Further information for Schneider Electric 18749 power switch 1-pole 80A
Additional features
Network frequency
50/60 Hz
[Ue] Operational rated voltage
380 - 415 V AC 50/60 Hz; 125 V DC;
Magnetic trip threshold
4 x In
[Ics] Rated operational breaking capacity
37.5 kA 75 % corresponds to EN/IEC 60947-2 - 220 - 240 V AC 50/60 Hz; 75 kA 75 % corresponds to EN/IEC 60947-2 - 110 - 130 V AC 50/60 Hz; 9.37 kA 75 % corresponds to EN/IEC 60947-2 - 380 - 415 V AC 50/60 Hz; 50 kA 100 % corresponds to EN/IEC 60947-2 - 60 V DC; 50 kA 100 % corresponds to EN/IEC 60947-2 - 125 V DC
50 kA Icu at 220 - 240 V AC 50/60 Hz complies with EN/IEC 60947-2; 100 kA Icu at 110 - 130 V AC 50/60 Hz complies with EN/IEC 60947-2; 50 kA Icu at 12 V DC complies with EN/IEC 60947-2; 50 kA Icu at 125 V DC complies with EN/IEC 60947-2; 36 kA Icu at
Application category
Category A corresponds to IEC 60947-2
Suitability for insulation
Yes, complies with IEC 60947-2
Standards
EN/IEC 60947-2
Mounting
Degree of protection (IP)
IP20 complies with IEC 60529
Degree of protection (IK)
IK05 corresponds to EN/IEC 62262
Pollution degree
3 corresponds to IEC 60947-2
Over voltage category
IV
Drip-proof
2 corresponds to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
2.000 m
Operating ambient temperature
-30…70 °C
Ambient temperature during storage
-40…70 °C
Packaging units
VPE 1 type
PCE
Number of devices per package
1
VPE 1 height
3 cm
VPE 1 width
8 cm
VPE 1 length
10,8 cm
Packaging weight (Lbs)
257 g
VPE 2 type
BB1
VPE 2 quantity
12
VPE 2 height
9 cm
VPE 2 width
11,7 cm
VPE 2 length
35,7 cm
VPE 2 weight
3,172 kg
VPE 3 type
S03
VPE 3 quantity
72
VPE 3 height
30 cm
VPE 3 width
30 cm
VPE 3 length
40 cm
VPE 3 weight
19,519 kg
Acti 9 NG125H circuit breaker, 36kA (IEC/EN 60947-2). 4-pole, nominal current 80A, C characteristic, operating voltage (Ue) 380-415V AC, insulation voltage (Ui) 690V AC. Protection of the circuit against short-circuit currents. Protection of the circuit against overload currents. Tripping is indicated by the middle position of the switch knob and by a red, mechanical display on the front of the device. Test button for checking the tripping mechanism. Power supply from above or below. Snap action for low-wear switching of the contacts. Technology of the tripping unit - thermomagnetic. Additional auxiliary modules that can be added in series (optional) - display of switch position, fault tripping, shunt release, undervoltage release, overvoltage release. The NG125H circuit breaker meets the following standards - IEC/EN 60947-2. Furthermore, this series is VDE certified.