Schmersal SRB504ST (101190714)
Schmersal SRB504ST (101190714)
Lieske Part No.
1331128
Mfg Part No
101190714
EAN-Code
Manufacturer
Schmersal
Here only
397,52 EUR
473,05 EUR incl. VAT
Further information for Schmersal SRB504ST (101190714)
Order Data:
Replaces Article Number: 101193473
Product Type: SRB504ST
Article Number (Order Number): 101190714
EAN (European Article Number): 4250116202300
eCl@ss Number:
Version 12.0: 27-37-18-19
Version 11.0: 27-37-18-19
Version 9.0: 27-37-18-19
ETIM Number:
Version 7.0: EC001449
Version 6.0: EC001449
Notice:
Discontinued Product
Approvals - Regulations:
Certificates:
- TÜV
- cULus
General Data:
Regulations:
- EN IEC 62061
- EN ISO 13849-1
- EN IEC 60947-5-1
- EN IEC 60947-5-3
- EN IEC 60947-5-5
- EN IEC 61508
- EN IEC 60204-1
- EN IEC 60947-1
Environmental Condition: EN 60068-2-78
Housing Material: Plastic, glass-fiber reinforced thermoplastic, ventilated
Gross Weight: 420 g
General Data - Features:
Electronic Fuse: Yes
Wire Break Detection: Yes
Cross-Short Detection: Yes
Removable Terminals: Yes
Start Input: Yes
Feedback Loop: Yes
Automatic Reset Function: Yes
Reset Edge Detection: Yes
Reset after Power Interruption: Yes
Ground Fault Detection: Yes
Integrated Status Display: Yes
Number of Auxiliary Contacts: 1
Number of LEDs: 6
Number of NC Contacts: 2
Number of Non-Delayed Semiconductor Outputs with Signaling Function: 3
Number of Safety Contacts: 5
Number of Signaling Outputs: 3
Safety Consideration:
Regulations:
- EN IEC 60947-5-1
- EN IEC 61508
Stop Category: 0
Mechanical Data:
Mechanical Lifespan, Minimum: 10,000,000 Switching Cycles
Mounting: Quick Mounting on Standard Rail According to DIN EN 60715
Connection Type: Screw Terminal M20 x 1.5
Connection Cross-Section, Minimum: 0.25 mm²
Connection Cross-Section, Maximum: 2.5 mm²
Terminal Torque: 0.6 Nm
Electrical Data:
Frequency Range: 50 Hz / 60 Hz
Operating Voltage: 24 VAC -15 % / +10 %, 24 VDC -10 % / +20 %
Ripple: 10 %
Rated Operating Voltage: 24 VAC / 24 VDC
Power Consumption: 3.2 W / 7.1 VA
Status Display:
Displayed Functions:
- Relay Position K2
- Relay Position K1
- Internal Operating Voltage Ui
- Relay Position K3
Note:
Inductive loads (contactors, relays, etc.) must be protected by appropriate circuits.
Circuit Example: 2-channel control suitable for contact amplification or multiplication through forced-guided contacts.
This is an offer of:
Lieske Elektronik e.K.
Reutener Str. 10
79279 Vörstetten
http://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111
Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1331128