Product description in English:
The BNS-B20-12Z-H is a magnetic safety sensor designed for demanding industrial applications. With its robust fiberglass-reinforced thermoplastic construction and IP67 protection, this sensor ensures reliability even in harsh environments. It provides safe monitoring of doors and protective equipment with a low coding level as per EN ISO 14119.
Equipped with 2 safety contacts (normally closed) and 1 normally open contact, the sensor offers flexible integration into safety circuits. The sensor features a holding force of 100 N and is suitable for doors with a maximum weight of 3 kg (sliding door) or 5 kg (swing door).
Technical Specifications:
Ordering Information:
- Product type: BNS-B20-12Z-H
- Article number: 101186262
- EAN: 4030661326825
- eCl@ss number: 27-27-44-01
- ETIM number: EC002544
Approvals and Standards:
- Certificates: cULus
- Standards: BG-GS-ET-14, EN IEC 60947-5-3
General Data:
- Coding level: Low (as per EN ISO 14119)
- Material: Fiberglass-reinforced thermoplastic
- Gross weight: 120 g
Mechanical Data:
- Actuation element: Magnet
- Door hinge: Right
- Holding force: 100 N
- Max. door weight: 3 kg (sliding door), 5 kg (swing door)
- Dimensions: Length 43.3 mm, Width 119.5 mm, Height 140 mm
Switching Distances (as per EN IEC 60947-5-3):
- Assured switching distance ON (Sao): 0 mm
- Assured switching distance OFF (Sar): 22 mm
Electrical Data:
- Max. switching voltage: 100 VAC / 100 VDC
- Max. switching current: 0.25 A
- Max. switching power: 3 W
- Max. switching frequency: 5 Hz
Connection Technology:
- Cable length: 1 m
- Cable entry: Rear
- Connection type: Cable
- Conductor cross-section: 0.25 mm²
- Cable sheath: PVC
Environmental Conditions:
- Protection class: IP67
- Operating temperature: -25 to +70 °C
- Vibration resistance: 10 … 55 Hz, Amplitude 1 mm
- Shock resistance: 30 g / 11 ms
Delivery:
Accessories:
- Recommended actuator: BNS-B20-B01
- Recommended safety relay modules: SRB-E-301ST, SRB-E-201LC
Notes:
- Devices with high inrush or cutoff peaks should be equipped with appropriate protective circuitry.
- Contact symbols are displayed with the protective device closed.
Circuit Example:
- Contact S21-S22 must be integrated into the safety circuit.