Product description in English:
The BNS 260-11Z-ST-L magnetic safety sensor is ideally suited for monitoring protective devices, offering reliable performance under the highest safety requirements. Designed specifically for left-hinged doors, the sensor is built with fiberglass-reinforced thermoplastic, ensuring durability and resistance to external influences.
With a low coding level according to EN ISO 14119 and a switching power of up to 10 VA, the sensor is versatile in its applications. Featuring a switching distance of up to 15 mm, one NO, and one NC contact, it meets stringent safety standards. The M8 connector provides a quick and secure electrical connection.
Technical specifications:
Ordering information:
- Product type: BNS 260-11Z-ST-L
- Article number: 101184379
- EAN: 4030661321776
- eCl@ss number: 27-27-44-01
- ETIM number: EC002544
Approvals and standards:
- Certifications: cULus
- Standards: BG-GS-ET-14, EN IEC 60947-5-3
General specifications:
- Coding level: Low
- Operating principle: Magnetic
- Material: Fiberglass-reinforced thermoplastic
- Gross weight: 32 g
Mechanical specifications:
- Door hinge: Left
- Movement direction: Frontal to the active surface
- Dimensions: Length 13 mm, Width 26 mm, Height 36 mm
- Switching distances:
- Secured switching distance ON (Sao): 5 mm
- Secured switching distance OFF (Sar): 15 mm
- Connection type: M8 connector, tightening torque: 0.3 Nm
Electrical specifications:
- Switching voltage: max. 75 VDC
- Switching current: max. 0.4 A
- Switching power: max. 10 VA
- Switching element: 1 normally open (NO), 1 normally closed (NC)
- Switching frequency: max. 5 Hz
Environmental conditions:
- Protection class: IP67
- Operating temperature: -25 °C to +70 °C
- Vibration resistance: 10–55 Hz, amplitude 1 mm
- Shock resistance: 30 g / 11 ms
Delivery:
- The actuator is not included in the scope of delivery.
Accessories:
- Recommended actuators: BPS 260
- Recommended safety control units: SRB-E-301ST, SRB-E-201LC
Notes:
- Pin assignment for versions with an integrated connector is specified in parentheses.
- Contacts S13-S14 and S21-S22 must be integrated into the safety circuit.