The AZ 16 ZVRK-M16 electromechanical safety switch is ideal for monitoring protective devices on machinery. It offers high reliability and safety due to ist robust design and positive-opening contacts.
Technical Data:
Product Designation:
Article Number:
EAN:
Certificates:
Standards and Regulations:
- EN ISO 13849-1
- EN ISO 14119
- EN IEC 60947-5-1
Coding Level:
- Low according to EN ISO 14119
Operating Principle:
Materials:
- Housing: Plastic, glass fiber-reinforced thermoplastic, self-extinguishing
Weight:
Features:
- Number of Approach Directions: 3
- Number of Safety Contacts: 1
- Number of Auxiliary Contacts: 1
- Number of Cable Entries: 3
Safety Considerations:
- Performance Level: Up to PL c
- Category: 1 (up to Category 3 with dual-channel use and suitable logic unit)
- B10D NC: 2,000,000 cycles
- B10D NO: 1,000,000 cycles (at 10 % Ie and resistive load)
- Service Life: 20 years
Mechanical Data:
- Mechanical Lifespan: Min. 1,000,000 cycles
- Latching Force: 30 N
- Positive Opening Distance: 8 mm
- Positive Opening Force per NC: Min. 10 N
- Maximum Actuation Speed: 2 m/s
- Mounting: Screws (2x M6)
Connection Technology:
- Cable Entry: 3 x M16 x 1.5
- Connection Type: Screw terminals
- Conductor Cross-section: 0.25–2.5 mm² (including ferrules)
- Permissible Cable Types: Solid single-wire, solid multi-wire, flexible
Dimensions:
- Length: 30 mm
- Width: 52 mm
- Height: 90 mm
Environmental Conditions:
- Protection Rating: IP67
- Ambient Temperature: -30 °C to +80 °C
- Storage and Transport Temperature: -40 °C to +85 °C
- Maximum Installation Height: 2,000 m
Electrical Data:
Thermal Continuous Current: 10 ARated Impulse Withstand Voltage: 6 kVRated Insulation Voltage: 500 VSwitching Element: 1 NO, 1 NCSwitching Principle: Slow-action, positive-opening NCMaximum Switching Frequency: 4,000 /hSafety Contacts:
Voltage AC-15: 230 VAC, Current: 4 AVoltage DC-13: 24 VDC, Current: 4 AAuxiliary Contacts:
Voltage AC-15: 230 VAC, Current: 4 AVoltage DC-13: 24 VDC, Current: 4 AScope of Delivery:
Slot seals for dust-tight covering of unused openings.