| General |
| Model | For 60 mm busbar systems |
| Material | Polyamide (PA 6), flammability rating according to UL 94, contact strips: electrolytic copper, silver-plated |
| Colour | RAL 9005, RAL 35745 |
| For rail systems with centre spacing | 60 mm |
| Cable exit | Below |
| Electrical connection type | Frame clamp |
| Fuse links | NH 000 |
| Rated insulation voltage Ui | 1.000 V |
| Rated current max. | 125 A |
| Rated operating voltage | 690 V AC |
| For NH size | 000 |
| Test basis | IEC/DIN EN 60 947-3, DIN EN 60 269-2 (fuse inserts) |
| Width | 53 mm |
| Height | 212 mm |
| Depth | 103 mm |
| Operating temperature range | -5 °C...35 °C |
| Storage temperature range | -25 °C...70 °C |
| Suitable for busbars | 15 x 5/10 mm, 20 x 5/10 mm, 30 x 5/10 mm |
| Suitable for busbar system | RiLineX, RiLine60 |
| Number of poles | 3-pole |
| Utility category | AC-23B (400 V/100 A), AC-22B (500 V/100 A), AC-21B (690 V/100 A), DC-22B (250 V/100 A) |
| Pollution degree | 3 |
| Degree of protection IP according to IEC 60 529 | IP 2XB |
| Fire load | 10,84 MJ/m² |
| Maximum power dissipation | 36 W |
| Power loss per fuse element (max.) | 9 W |
| Copper content (kg/piece) | 0,404 |
| PCF/VE (Cradle-to-Gate) | 4,82 |
The Rittal RX 9362421 is an
NH fuse switch disconnector in size 000, specifically designed for 60 mm busbar systems. It serves as a
switch disconnector with integrated fuse inserts and enables safe disconnection of power supply in industrial installations. The device is intended for use in enclosures and distributions where reliable power interruption and monitoring are required. The design is for busbar systems with a center-to-center spacing of 60 mm, supporting busbar thicknesses of 5 mm and 10 mm in widths of 15 mm, 20 mm, and 30 mm. Mounting is done via push-on mounting, with tool-free adjustment to the busbar thickness.
Applications
The switch disconnector is intended for industrial applications in the field of power distribution and protection. It is used in enclosures, distributions, and machine controls where safe disconnection of power supply is required for maintenance work or in case of faults. The rated operational voltage is 690 V AC, and the rated insulation voltage Ui is 1,000 V, making it suitable for installations with high voltages. The maximum rated current is 125 A, with usage categories AC-23B, AC-22B, AC-21B, and DC-22B defining the operating conditions for alternating and direct current.
Functions and Equipment in Detail
The cover of the switch disconnector is
lockable and
sealable, preventing unauthorized manipulation. The
visual fuse monitoring allows direct inspection of the installed NH fuse inserts (size 000). The
safe voltage testing is performed via integrated test points on the cover, accessible through a separate opening. This ensures safe voltage testing without fully opening the cover. A
parking position for the cover facilitates maintenance work, as the cover can be held in a stable, half-open position.
Technology Explained Simply
The electrical connection is made via a
frame terminal, designed for connecting round conductors with a cross-section of at least 1.5 mm² up to a maximum of 50 mm². The
conductor exit is at the bottom, enabling flexible cabling. The contact strips are made of
electrolytic copper, silver-plated, ensuring high electrical conductivity and corrosion resistance. The housing is made of
polyamide (PA 6), which meets specific flammability requirements according to UL 94. The protection class IP 2XB according to IEC 60 529 protects against finger contact and vertical dripping water, but not against splashing water or dust. The operating temperature range is between -5 °C and 35 °C, and the storage temperature range is between -25 °C and 70 °C.
Compatibility and Accessories
The switch disconnector is compatible with the busbar systems
RiLineX and
RiLine60. Suitable accessories are available, including the
enclosure protection profile RX 9365025 (length 1200 mm),
mounting clips RX 9365027, the
microswitch RX 9365500, and the
anti-shift clip RX 9365501, which enhance safety functions and mechanical stability.
Mounting and Installation
Mounting is done via push-on mounting onto the busbars, with tool-free adjustment to the busbar thickness. The frame terminal enables secure and easy connection of conductors. The bottom cable exit provides flexibility in cabling. Dimensions are 53 mm (width) × 212 mm (height) × 103 mm (depth), enabling compact integration into enclosures.
Advantages in Operation
The switch disconnector offers high safety through lockable and sealable cover, as well as visual and electrical monitoring of fuse inserts. The parking position and integrated test points for voltage testing reduce maintenance time and increase work safety. The tool-free adjustment to various busbar thicknesses and the compact design simplify installation and replacement. The power loss is a maximum of 36 W, with up to 9 W per fuse insert. The fire load is 10.84 MJ/m², meeting fire protection requirements in industrial installations. The testing basis is according to IEC/DIN EN 60 947-3 and DIN EN 60 269-2 for the fuse inserts.