| General |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 845 mm |
| Number of sockets and type | 9 x C19 |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 11 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,200 mm |
The Rittal DK 7979230 is a
PDU (Power Distribution Unit) with integrated energy measurement, specifically designed for use in IT network and server racks. As a
metered-PDU, it offers detailed measurement functions per phase and input, enabling precise monitoring of the energy consumption of an entire rack. The device features a compact design with dimensions of 44 mm (width) × 845 mm (length) × 70 mm (depth) and is suitable for vertical mounting in the Zero-U-Space of Rittal VX IT- or TS IT-racks, with tool-free installation. The power distribution is constructed from an
aluminum profile, black anodized, with sockets made of
plastic. Mounting materials are included in the delivery scope.
Applications
The PDU is designed for use in IT infrastructures, particularly in data centers, server rooms, and network-server racks. It is suitable for power distribution and monitoring in environments where precise energy accounting and redundant power supply are required. The integrated energy measurement enables detailed analysis of energy consumption, allowing for operational optimizations and efficient resource utilization. The PDU is designed for racks with a minimum length of 1,200 mm, compatible with both VX IT-enclosure frames and 48,3 cm ( 19 inch ) profile rails.
Functions and Equipment in Detail
The DK 7979230 features 9 sockets of type
C19, suitable for connecting IT devices with high power demand. The rated operating voltage is 400 V (AC), with a maximum rated current of 16 A, corresponding to a rated power of 11 kW. Power supply is via a CEE input cable with a length of 3 m. The PDU is
self-powered, meaning it does not require external power for its control and measurement functions. An integrated real-time clock with battery backup (up to 10 years, replaceable) ensures accurate timestamping of measurement data. Measurement accuracy is ±1 % (kWh) according to standard
EN 62053-21.
Technology Explained Simply
The PDU features a powerful CPU (ARM Cortex A8) that handles measurement and control functions. Measurements are taken per phase and input, capturing voltage, current, frequency, active power, apparent power, power factor (cosPhi), phase angle, and neutral conductor current. Load imbalance detection enables identification of uneven load distribution. The PDU includes a bright TFT display (128x128 pixels, RGB) with backlight and energy-saving mode, showing performance data and basic configuration. The display unit is rotatable by 180° and replaceable, ensuring optimal readability during vertical mounting. An integrated electromagnetic buzzer provides acoustic alarm for exceeding set thresholds for voltage, current, or power. Operating hour counters are both total and cyclic resettable.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces to integrate into existing IT infrastructures and DCIM systems (Data Center Infrastructure Management). The fully redundant Ethernet interface (10/100/1000 Mbit/s) enables stable network connectivity. Configurations, firmware updates, data logging, and scripts can be performed via interfaces
USB 2.0 (USB-A),
CAN-Bus (RJ45), and
RS232 (RJ12). The PDU supports protocols such as
HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1/v2c/v3, Modbus/TCP, OPC-UA, as well as MIBs for integration into third-party DCIM software. E-mail alerts (SMTP) and Syslog server connection (up to 2 servers) are also possible. User management includes rights management and integration with LDAP(S), Radius, or Active Directory. Optionally,
CMC III CAN-Bus sensors can be connected to monitor environmental data such as temperature or humidity — up to 16 sensors are possible. Compatible accessories include CAN-Bus cables in various lengths, covers for C13 and C19 sockets, mounting adapters, universal locks, numeric code locks, transponder readers, and a surge protection module (Type 3) with replaceable discharge elements during operation and status monitoring.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT- or TS IT-racks. The PDU is designed for racks with a minimum length of 1,200 mm. Phase color coding (L1=pink, L2=black, L3=white) facilitates assignment and installation. The integrated power supply is fault-tolerant and redundantly designed across all phases, ensuring high availability. The PDU is designed for operation in environments with temperatures from 5 °C to 50 °C and humidity from 10 % to 95 % (non-condensing). Storage temperature ranges from -20 °C to 70 °C.
Operational Advantages
The DK 7979230 offers high measurement accuracy, redundant power supply, and comprehensive network integration. The integrated real-time clock and battery backup ensure data continuity. The ability to set thresholds for voltage, current, and power enables proactive monitoring and alerting. Support for DCIM systems and integration into existing networks simplifies centralized management and control. The energy-efficient design with low self-consumption reduces the PDU’s own energy demand. Integrated fuse monitoring and the ability to perform differential current measurement (Type B) per input/phase/fuse enhance operational safety. The PDU complies with IT infrastructure requirements according to directives
EMC Directive 2014/30/EU and
Low Voltage Directive 2014/35/EU, as well as standards
EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21.