| General |
| Model | Wall mounting, EMC |
| Material | Plastic |
| Colour | RAL 7035 |
| Scope of delivery | Complete ready-to-install unit, including EMI filter mat |
| Fan | Diagonal, 1~ capacitor motor |
| Airflow free-blowing (with filter) | At 50 Hz: 540 m³/h, At 60 Hz: 590 m³/h |
| Airflow with associated exhaust filter including felt filter | At 50 Hz: 444 m³/h, At 60 Hz: 498 m³/h |
| Rated operating voltage | 115 V, 1~, 50 Hz/60 Hz |
| Rated power Pel | At 50 Hz: 78.7 W, At 60 Hz: 102.8 W |
| Rated current max. | At 50 Hz: 0.81 A, At 60 Hz: 0.9 A |
| Width | 323 mm |
| Height | 323 mm |
| Depth | 144,5 mm |
| Built-in depth | 124 mm |
| Mounting cutout | Cutout width: 292 mm, Cutout height: 292 mm |
| Degree of protection IP according to IEC 60 529 | IP 54 with felt filter, IP 56 with felt filter and spray hood |
| NEMA degree of protection | Type 12 with felt filter, Type 3, 3R, 4, 4X with felt filter and spray shield |
| Fuse | Circuit breaker/fuse: 6 A |
| Note | To improve energy efficiency and increase device lifespan, use of temperature controllers or indicators is recommended. |
| Operating temperature range | -30 °C...55 °C |
| Storage temperature range | -30 °C...70 °C |
| Sound pressure level | At 50 Hz: 62 dB(A), At 60 Hz: 65 dB(A) |
The Rittal SK 3243.810 is an
EMV filter fan for enclosure climate control, designed for wall mounting and operation in industrial environments. The unit features a
plastic housing in the colour
RAL 7035 and is delivered as a complete, ready-to-install unit, including an
EMV filter mat. It is used for controlled ventilation of enclosures to regulate internal temperature and ensure the proper function of electronic components.
Applications
This filter fan is designed for use in industrial plants where efficient and reliable climate control of enclosures is required. It is particularly suitable for environments with high dust loads or electromagnetic compatibility (EMV) requirements, as it meets requirement level 2 according to
EN 61587-3. The integrated EMV shielding provides high attenuation of electromagnetic interference, supporting the stability of sensitive electronic devices within the enclosure.
Functions and Equipment in Detail
The unit operates with a
diagonal fan based on a
1~ capacitor motor. The air flow rate is 540 m³/h at 50 Hz and 590 m³/h at 60 Hz when operating freely with a non-woven filter. When using an additional outlet filter, the air flow rate reduces to 444 m³/h (50 Hz) or 498 m³/h (60 Hz).
Tool-free mounting is achieved via optimised latching hooks, enabling faster installation on the enclosure. A new opening mechanism on the louver grille facilitates filter replacement.
Technology Explained Simply
The
diagonal fan technology ensures more uniform and consistent ventilation of the enclosure due to higher pressure stability. This prevents local overheating and ensures homogeneous air circulation. The
rated operating voltage is 115 V, 1~, and is designed for frequencies of 50 Hz and 60 Hz. The rated power is 78.7 W (50 Hz) or 102.8 W (60 Hz), with a maximum rated current of 0.81 A (50 Hz) or 0.9 A (60 Hz). The
fuse is rated for 6 A to protect the fan from overloads.
Compatibility and Accessories
The fan is equipped with a non-woven filter, providing protection class
IP 54. With an additional spray hood, it achieves
IP 56. According to NEMA standards, it corresponds to
Type 12 with non-woven filter, and
Type 3, 3R, 4, 4X with non-woven filter and spray hood. Compatible accessories include the
Blue e+ outlet filter EMV, RAL 7035, which can be used to enhance air purification and protection class.
Mounting and Installation
The installation dimensions are 323 mm (width) × 323 mm (height) × 144.5 mm (depth), with an installation depth of 124 mm. The mounting cutout requires a hole of 292 mm (width) × 292 mm (height). The tool-free mounting allows for quick and secure installation on the enclosure wall.
Operational Advantages
The operating temperature range is from -30 °C to +55 °C, and the storage temperature range is from -30 °C to +70 °C. The sound pressure level is 62 dB(A) at 50 Hz and 65 dB(A) at 60 Hz, representing acceptable noise emissions for industrial applications. The recommendation to use temperature controllers or indicators supports energy efficiency and extends the service life of the device through targeted operation control.