| General |
| Model | Wall mounting, EMC |
| Material | Plastic |
| Colour | RAL 7035 |
| Scope of delivery | Complete ready-to-install unit, including EMI filter mat |
| Fan | Diagonal, split-pole motor |
| Airflow free-blowing (with filter) | At 50 Hz: 175 m³/h, at 60 Hz: 157 m³/h |
| Airflow with associated exhaust filter including felt filter | At 50 Hz: 130 m³/h, At 60 Hz: 112 m³/h |
| Rated operating voltage | 230 V, 1~, 50 Hz/60 Hz |
| Rated power Pel | At 50 Hz: 33.1 W, At 60 Hz: 37.3 W |
| Rated current max. | At 50 Hz: 0.2 A, At 60 Hz: 0.21 A |
| Width | 255 mm |
| Height | 255 mm |
| Depth | 129 mm |
| Built-in depth | 108 mm |
| Mounting cutout | Cutout width: 224 mm, cutout height: 224 mm |
| Degree of protection IP according to IEC 60 529 | IP 54 with felt filter, IP 56 with felt filter and spray hood |
| NEMA degree of protection | Type 12 with felt filter, Type 3, 3R, 4, 4X with felt filter and spray shield |
| Fuse | Circuit breaker/fuse: 2 A |
| Note | To improve energy efficiency and increase device lifespan, use of temperature controllers or indicators is recommended. |
| Operating temperature range | -30 °C...55 °C |
| Storage temperature range | -30 °C...70 °C |
| Sound pressure level | At 50 Hz: 48 dB(A), At 60 Hz: 45 dB(A) |
The Rittal SK 3240.800 is a
filter fan with
EMC shielding, designed for
enclosure climate control in industrial applications. The device serves for controlled ventilation of enclosures, regulating internal temperature and ensuring the functionality of sensitive electronic components. It is designed for
wall mounting and consists of
plastic in the colour
RAL 7035. The unit is
fully ready for installation and includes the
EMC filter mat. Installation is
tool-free via optimised snap hooks, accelerating the mounting process on the enclosure.
Applications
The filter fan is suitable for use in industrial environments where continuous and reliable ventilation of enclosures is required. It is particularly suited for systems equipped with electronic controls, power electronics, or other sensitive components. The EMC shielding meets requirement level 2 according to
EN 61587-3, ensuring high attenuation of electromagnetic interference. This minimises interference with sensitive devices inside the enclosure.
Functions and Equipment in Detail
The fan features
diagonal fan technology with a split-pole motor, providing higher pressure stability and thus enabling more uniform and consistent air circulation within the enclosure. The air performance is
175 m³/h at 50 Hz and
157 m³/h at 60 Hz when free-blowing (with non-woven filter). When used with the corresponding outlet filter including non-woven filter, the air performance reduces to
130 m³/h at 50 Hz and
112 m³/h at 60 Hz. The
rated operating voltage is
230 V, 1~, 50 Hz/60 Hz, enabling universal use in various power networks. The
rated power is
33.1 W (50 Hz) or
37.3 W (60 Hz), and the
rated current is maximum
0.2 A (50 Hz) or
0.21 A (60 Hz). The
fuse is rated at
2 A.
Technology Explained Simply
The
diagonal fan technology ensures improved pressure stability, which is particularly beneficial at higher air resistance levels within the enclosure. Air is distributed evenly, resulting in consistent cooling performance. The
EMC shielding protects against electromagnetic interference generated by other devices within the enclosure or from the surrounding environment. The
filter mat provides mechanical separation of dust and particles, increasing air cleanliness inside the enclosure. The
tool-free mounting via snap hooks reduces installation time and simplifies replacement.
Compatibility and Accessories
The fan can be combined with various accessories to extend functionality. These include the
Blue e+ outlet filter EMC in RAL 7035, which further improves air cleanliness. For precise temperature control, a
thermostat enclosure internal temperature controller, a
speed controller for filter fans, or a
digital temperature display and control can be used. The
spray water hood made of stainless steel increases the protection rating to
IP 56 (according to IEC 60 529) and
Type 3, 3R, 4, 4X (according to NEMA), enabling use in outdoor or damp environments. A
hygrostat can be used for humidity control.
Mounting and Installation
Mounting is tool-free onto the enclosure wall. The mounting cutout measures
224 mm (width) x 224 mm (height). The installation depth of the device is
108 mm, and the overall dimensions are
255 mm (width) x 255 mm (height) x 129 mm (depth). The unit is designed for installation on flat surfaces and adapts to standard enclosure front panels.
Operational Advantages
The operating temperature range is between
-30 °C and 55 °C, and the storage temperature can reach up to
70 °C. The
sound pressure level is
48 dB(A) at 50 Hz and
45 dB(A) at 60 Hz, ensuring quiet operation. The recommended use of temperature controllers or displays contributes to energy efficiency and extends the device's service life. The
IP protection class 54 (with non-woven filter) and
IP 56 (with non-woven filter and spray water hood), as well as
NEMA Type 12 (with non-woven filter) and
Type 3, 3R, 4, 4X (with non-woven filter and spray water hood), ensure high protection against dust and splashing water. The
EMC shielding ensures reliable operation in electromagnetically demanding environments.