| General |
| Model | Wall mounting, EMC |
| Material | Plastic |
| Colour | RAL 7035 |
| Scope of delivery | Complete ready-to-install unit, including EMI filter mat |
| Fan | Axial, split-pole motor |
| Airflow free-blowing (with filter) | At 50 Hz: 100 m³/h, At 60 Hz: 115 m³/h |
| Airflow with associated exhaust filter including felt filter | At 50 Hz: 75 m³/h, At 60 Hz: 86 m³/h |
| Rated operating voltage | 230 V, 1~, 50 Hz/60 Hz |
| Rated power Pel | At 50 Hz: 14.7 W, At 60 Hz: 16.5 W |
| Rated current max. | At 50 Hz: 0.1 A, At 60 Hz: 0.12 A |
| Width | 204 mm |
| Height | 204 mm |
| Depth | 105 mm |
| Built-in depth | 84 mm |
| Mounting cutout | Cutout width: 177 mm, cutout height: 177 mm |
| Degree of protection IP according to IEC 60 529 | IP 54 with felt filter, IP 56 with felt filter and spray hood |
| NEMA degree of protection | Type 12 with felt filter, Type 3, 3R, 4, 4X with felt filter and spray shield |
| Fuse | Circuit breaker/fuse: 2 A |
| Note | To improve energy efficiency and increase device lifespan, use of temperature controllers or indicators is recommended. |
| Operating temperature range | -15 °C...55 °C |
| Storage temperature range | -30 °C...70 °C |
| Sound pressure level | At 50 Hz: 51 dB(A), At 60 Hz: 54 dB(A) |
Rittal SK 3239.800 is an
EMV filter fan for
enclosure climate control, designed as a
wall-mounted unit. It is intended for controlled ventilation of enclosures to regulate internal temperature and ensure the operational reliability of electronic components. The device is made of
plastic and available in the color
RAL 7035, enabling visual harmonization with standard enclosure fronts. The unit is
fully ready for installation and includes an
EMV filter mat that reduces electromagnetic interference and meets requirement class 2 according to
EN 61587-3.
Applications
The filter fan is designed for use in industrial environments where targeted ventilation of enclosures is required to ensure heat dissipation and dust filtration. It is particularly suitable for systems operating in areas with high electromagnetic compatibility (EMV) requirements, such as in automation technology, manufacturing industry, or energy technology. The integrated EMV shielding protects sensitive electronic components from disturbances caused by electromagnetic fields.
Functions and Equipment in Detail
The fan features an
axial fan with split-pole motor, ensuring reliable and quiet air movement. The air performance is
100 m³/h at 50 Hz and
115 m³/h at 60 Hz when free-blowing, while it reduces to
75 m³/h (50 Hz) and
86 m³/h (60 Hz) when used with a matching outlet filter including a felt filter. The
sound pressure levels are
51 dB(A) at 50 Hz and
54 dB(A) at 60 Hz, enabling acoustically pleasant operation in sensitive environments. The
rated operating voltage is
230 V, 1~, 50 Hz/60 Hz, making the unit usable in various power networks worldwide. The
rated power is
14.7 W (50 Hz) and
16.5 W (60 Hz), with the
rated current reaching a maximum of
0.1 A (50 Hz) or
0.12 A (60 Hz).
Technology Explained Simply
The
diagonal fan technology ensures higher pressure stability, resulting in more uniform and consistent air distribution within the enclosure. This improves cooling performance and reduces the risk of local overheating. The
opening mechanism on the louver grille allows for easy filter replacement, simplifying maintenance. The
optimized latching hooks enable faster installation on the enclosure, and the unit can be mounted without tools. The
installation depth is 84 mm, and the required
mounting cutout has a cutout width and height of
177 mm each.
Compatibility and Accessories
The fan is equipped with a
felt filter that retains dust and particles. The protection class
IP 54 is achieved when the felt filter is installed; with a
spray water hood, the protection class increases to
IP 56. Correspondingly, the NEMA protection classes
Type 12 (with felt filter) and
Type 3, 3R, 4, 4X (with felt filter and spray water hood) are attainable. Suitable accessories include
Blue e+ outlet filters EMV,
stainless steel spray water hoods,
thermostats,
speed controllers,
digital temperature displays, and
hygrostats, which can be used for precise temperature and humidity control within the enclosure.
Mounting and Installation
Mounting is tool-free on the enclosure wall. The dimensions of the unit are
204 mm (width) × 204 mm (height) × 105 mm (depth). The installation depth of
84 mm must be considered within the enclosure. A mounting cutout of
177 mm × 177 mm must be provided in the enclosure. The unit is designed for an
operating temperature range of -15 °C to 55 °C, with a
storage temperature up to
70 °C. A
fuse of 2 A is required to ensure electrical safety.
Advantages in Operation
The combination of EMV shielding, high air performance, and tool-free installation makes the SK 3239.800 a reliable solution for enclosure climate control. The recommended use of
temperature controllers or displays can increase energy efficiency and extend the service life of the fan unit, as the fan is activated only when needed. The integrated
EMV filter mat provides high damping effect, supporting the functionality of sensitive electronic devices within the enclosure. The
protection class IP 56 (with spray water hood) enables use in humid or dusty environments, which are common in industrial applications.