| General |
| Model | Wall mounting, EMC |
| Material | Plastic |
| Colour | RAL 7035 |
| Scope of delivery | Complete ready-to-install unit, including EMI filter mat |
| Fan | Axial, split-pole motor |
| Airflow free-blowing (with filter) | At 50 Hz: 53 m³/h, At 60 Hz: 64 m³/h |
| Airflow with associated exhaust filter including felt filter | At 50 Hz: 40 m³/h, At 60 Hz: 46 m³/h |
| Rated operating voltage | 115 V, 1~, 50 Hz/60 Hz |
| Rated power Pel | At 50 Hz: 15.4 W, at 60 Hz: 15.8 W |
| Rated current max. | At 50 Hz: 0.2 A, At 60 Hz: 0.21 A |
| Width | 148,5 mm |
| Height | 148,5 mm |
| Depth | 82,5 mm |
| Built-in depth | 64 mm |
| Mounting cutout | Cutout width: 124 mm, cutout height: 124 mm |
| Degree of protection IP according to IEC 60 529 | IP 54 with felt filter, IP 56 with felt filter and spray hood |
| NEMA degree of protection | Type 12 with felt filter, Type 3, 3R, 4, 4X with felt filter and spray shield |
| Fuse | Circuit breaker/fuse: 2 A |
| Note | To improve energy efficiency and increase device lifespan, use of temperature controllers or indicators is recommended. |
| Operating temperature range | -15 °C...55 °C |
| Storage temperature range | -30 °C...70 °C |
| Sound pressure level | At 50 Hz: 52 dB(A), At 60 Hz: 54 dB(A) |
The Rittal SK 3238.810 is an
EMV filter fan for wall mounting in enclosures and technical housings. It serves
enclosure climate control through controlled ventilation and filtration of supply air, thereby keeping dust, particles, and other contaminants away from the interior space. The unit is designed as a
fully ready-to-install unit and includes the
EMV filter mat, which ensures high shielding and damping performance. The design meets requirement level 2 according to EN 61587-3, ensuring high electromagnetic compatibility.
Applications
The fan is designed for use in industrial and technical installations where continuous, dust-free ventilation is required. It is particularly suitable for enclosures in production environments, automation technology, machine building, and installations operating in areas with increased dust exposure. The
wall mounting allows for flexible integration into existing enclosure constructions.
Functions and Equipment in Detail
The fan features an
axial fan with split-pole motor, ensuring uniform and constant air circulation. The
diagonal fan technology provides improved air distribution within the enclosure due to higher pressure stability. The
easy filter replacement is enabled by a new opening mechanism on the louver grille, simplifying maintenance. Installation is
tool-free using optimized snap hooks, accelerating the setup process.
Technology Explained Simply
The air performance is
53 m³/h at 50 Hz and
64 m³/h at 60 Hz under free-blowing operation (with felt filter). When using an additional outlet filter, the air performance drops to
40 m³/h at 50 Hz and
46 m³/h at 60 Hz. The rated operating voltage is
115 V, 1~, 50 Hz/60 Hz, enabling universal use in various power networks. The rated power is
15.4 W at 50 Hz and
15.8 W at 60 Hz, with a maximum rated current of
0.2 A and 0.21 A respectively. The sound pressure level is
52 dB(A) at 50 Hz and
54 dB(A) at 60 Hz, representing an acoustically acceptable operating noise level. The operating temperature range is from
-15 °C to 55 °C, and the storage temperature range is from
-30 °C to 70 °C.
Compatibility and Accessories
The fan is equipped with a
felt filter, ensuring IP 54 protection rating according to IEC 60 529. When used with a
spray water hood, the protection rating increases to IP 56. Correspondingly, NEMA protection ratings Type 12 (with felt filter) and Type 3, 3R, 4, 4X (with felt filter and spray water hood) are achievable. Compatible accessories include
Blue e+ outlet filter EMV,
thermostat enclosure internal temperature controller,
speed controller for filter fans,
digital temperature display and control,
SK spray water hood, and
hygrostat. The use of temperature controllers or displays is recommended to improve energy efficiency and extend the device’s service life.
Mounting and Installation
The unit is mounted on the enclosure wall, requiring a mounting cutout with a breakout width and height of
124 mm each. The installation depth is
64 mm, and the overall dimensions are
148.5 mm (width) × 148.5 mm (height) × 82.5 mm (depth). The tool-free mounting and optimized snap hooks allow for quick and secure installation without additional tools.
Operational Advantages
The fan provides reliable, dust-free ventilation, extending the service life of electronic components within the enclosure. The EMV shielding protects against electromagnetic interference. Easy maintenance via the new opening mechanism and tool-free mounting reduces maintenance effort. The combination of high air flow and low noise level ensures efficient and quiet operation. The use of additional controllers enables intelligent fan speed control based on temperature requirements, saving energy and enhancing operational safety.