| General |
| Model | Wall surface mounted |
| Material | Plastic |
| Colour | RAL 9005 |
| Scope of delivery | Complete ready-to-install unit, including pleated filter |
| Fan | Axial, split-pole motor |
| Airflow free blowing (with pleated filter) | At 50 Hz: 63 m³/h, At 60 Hz: 72 m³/h |
| Airflow with associated exhaust filter including pleated filter | At 50 Hz: 49 m³/h, at 60 Hz: 55 m³/h |
| Airflow free-blowing (with filter) | At 50 Hz: 53 m³/h, At 60 Hz: 64 m³/h |
| Airflow with associated exhaust filter including felt filter | At 50 Hz: 40 m³/h, At 60 Hz: 46 m³/h |
| Rated operating voltage | 115 V, 1~, 50 Hz/60 Hz |
| Rated power Pel | At 50 Hz: 15.4 W, at 60 Hz: 15.8 W |
| Rated current max. | At 50 Hz: 0.2 A, At 60 Hz: 0.21 A |
| Width | 148,5 mm |
| Height | 148,5 mm |
| Depth | 82,5 mm |
| Built-in depth | 64 mm |
| Mounting cutout | Cutout width: 124 mm, cutout height: 124 mm |
| Degree of protection IP according to IEC 60 529 | IP 54 with nonwoven filter/pleated filter, IP 55 with pleated filter and absorber mat, IP 56 with nonwoven filter/pleated filter and spray water hood |
| NEMA degree of protection | Type 12 with felt filter/pleated filter, Type 3, 3R, 4, 4X with felt filter/pleated filter and spray water hood |
| Fuse | Circuit breaker/fuse: 2 A |
| Note | For the filter fan 3237.XXX, the electrical connection is made via 2 individual wires (approx. 300 mm length) on the device; for all other filter fans, via spring clamp terminal. |
| Operating temperature range | -15 °C...55 °C |
| Storage temperature range | -30 °C...70 °C |
| Sound pressure level | At 50 Hz: 52 dB(A), At 60 Hz: 54 dB(A) |
The Rittal SK 3238.718 is a
filter fan for
enclosure climate control, designed as a
wall-mounted unit. It is intended for controlled ventilation of enclosures to regulate internal temperature and extend the service life of installed electronic components. The device is made of
plastic and available in the color
RAL 9005, enabling visual integration into industrial environments. The delivery includes a
fully ready-to-install unit including pleated filter, which can be directly installed into the enclosure.
Applications
The filter fan is intended for use in industrial plants, machine construction, automation technology, and other areas where continuous cooling of electronic components is required. It is particularly suitable for enclosures operated in environments with dust, fine particle contamination, or low humidity. The integrated filter technology ensures that incoming air is cleaned, thereby reducing contamination of internal components.
Functions and Equipment in Detail
The fan features
diagonal fan technology, providing higher pressure stability and more consistent airflow. The diagonal exhaust direction ensures more even cooling of the enclosure. The airflow rate is
63 m³/h at 50 Hz and
72 m³/h at 60 Hz when using the integrated pleated filter. With a nonwoven filter, the values are
53 m³/h (50 Hz) and
64 m³/h (60 Hz). The airflow decreases to
49 m³/h (50 Hz) and
55 m³/h (60 Hz) with pleated filter, or
40 m³/h (50 Hz) and
46 m³/h (60 Hz) with nonwoven filter when an outlet filter is used. The
rated power is
15.4 W at 50 Hz and
15.8 W at 60 Hz, with a
rated current of max.
0.2 A (50 Hz) or
0.21 A (60 Hz). The
rated operating voltage is
115 V, 1~, 50 Hz/60 Hz.
Technology Explained Simply
The fan is an
axial fan with a split-pole motor, designed for reliable and quiet operation. The
protection rating IP 54 is achieved standard when using nonwoven or pleated filters. With an additional absorber mat, the device reaches
IP 55, and with a spray hood,
IP 56 is achieved. The
protection rating NEMA Type 12 is achieved with nonwoven or pleated filters, while
Type 3, 3R, 4, 4X are achieved with nonwoven or pleated filters and a spray hood. The
sound pressure level is
52 dB(A) at 50 Hz and
54 dB(A) at 60 Hz, enabling acoustically pleasant operation in industrial environments. The
operating temperature range is between
-15 °C and 55 °C, and the
storage temperature range is between
-30 °C and 70 °C.
Compatibility and Accessories
Various accessories are available for the filter fan to extend its functionality. These include
outlet filters in RAL 9005,
replacement filter mats in various types, a
spray hood for increased protection rating, an
absorber mat for IP 55, and
speed controllers for adjusting airflow. A
thermostat or
hygrostat can be used for temperature or humidity control. A
blanking cover is available to close the mounting opening if the fan is not used. Electrical connection is made via
spring clamp terminal, with a
fuse of 2 A provided.
Mounting and Installation
Mounting is tool-free using optimized snap hooks, enabling quick and secure attachment to the enclosure. The mounting cutout measures
124 mm (width) x 124 mm (height), and the installation depth is
64 mm. The device dimensions are
148.5 mm (width) x 148.5 mm (height) x 82.5 mm (depth). The
pleated filters are included in the delivery and can be easily replaced thanks to a new opening mechanism on the louver grid.
Advantages in Operation
The SK 3238.718 offers high airflow, maximized by the integrated pleated filter in the delivered state. The diagonal fan technology ensures even and consistent ventilation, increasing cooling efficiency. Tool-free mounting and easy filter replacement reduce installation and maintenance time. The high protection rating allows use in various industrial environments, and the combination with accessories such as spray hood or absorber mat enables adaptation to specific requirements. The operating voltage of 115 V is common in many industrial plants, increasing compatibility. The low rated power and moderate sound pressure level contribute to energy-efficient and quiet operation.