| General |
| Manufacturer | Mushroom |
| Operating voltage | 24 V AC/DC |
| Inputs | 1/2-channel wiring with/without cross-connection detection |
| Outputs | 3 S, 1 Ö, 1 HL |
| Start function | Automatic/supervised start |
| Clamps | Screw terminals, plug-in type |
| Monitoring function | Emergency stop, safety doors |
| Accessory compatibility | PNOZXSETPLUGINSCREWTERMINALSP3+P4 |
The safety control device PNOZ X3P 24VDC/24VAC, type 777310, from Pilz is a standalone system for the safe control of machines and plants. It is used for monitoring emergency stop functions and safety doors and enables the safe deactivation of drives or other hazardous movements in case of a fault or dangerous situation. The device is designed for use in industrial environments where high safety integrity is required and supports integration into existing safety architectures.
Applications
The device is used in industrial automation, particularly in machine building, conveying technology, and packaging technology. It monitors safety-relevant functions such as emergency stop switches, safety doors, and other mechanical or electrical safety components. The 1/2-channel wiring allows flexible connection to various safety sensors, with the option of with or without cross-connection detection depending on requirements. Monitoring of emergency stop and safety doors is performed via integrated inputs, ensuring a safe response to hazardous situations.
Functions and Equipment in Detail
The safety control device features three safe outputs (3 S), one normally open contact (1 Ö), and one auxiliary reset contact (1 HL). These outputs enable control of external safety components, such as stop relays, emergency stop relays, or indicator lights. The automatic or monitored start function ensures that the machine can only be started when all safety conditions are met. The plug-in screw terminals facilitate installation and maintenance by enabling quick and secure connection of cables.
Technology Explained Simply
The device operates with a supply voltage of 24 V AC/DC, enabling universal use in many industrial plants. The width of 45 mm corresponds to the standard format for safety relays and fits into common enclosures. The integrated monitoring function ensures that the device checks its own functions and safely deactivates outputs in case of faults or disturbances. Cross-connection detection identifies if a cable between two inputs has been severed, providing an additional safety level.
Compatibility and Accessories
The device is compatible with the accessory PNOZXSETPLUGINSCREWTERMINALSP3+P4, which provides plug-in screw terminals for connections P3 and P4. These terminals simplify installation and maintenance, especially during frequent adjustments or maintenance. Combining the device with this accessory enables flexible and secure wiring without requiring additional tools or special mounting methods.
Mounting and Installation
Mounting is performed in a standard enclosure. The plug-in screw terminals allow for quick and secure cable connections. The width of 45 mm corresponds to the DIN format, allowing the device to be installed in standard enclosure modules. Installation requires no special tools, as the terminals can be directly plugged in and screwed. The terminal assignment is standardized, allowing wiring according to common standards.
Advantages in Operation
The device offers high safety integrity through integrated monitoring and the option of 1/2-channel wiring. The plug-in screw terminals reduce installation time and simplify maintenance. The supply voltage of 24 V AC/DC enables flexible integration into existing systems. The monitored start function ensures that the machine can only be started when all safety conditions are met, increasing operational safety.