| General |
| Type of device | safety switchgear |
| Operation mode | Standalone |
| Inputs | 1/2-channel wiring with/without cross-connection detection |
| Outputs | 3 S, 2 Sz |
| Operating voltage | 24 V DC |
| Connection type | Integrated screw terminals |
| Function | Monitoring of emergency stop, safety doors with 2 delayed return contacts |
| Reset time | 12 steps from 0.1 - 30 s |
| Accessories | Protective cap P-93(V |
The safety control device PNOZXV3 from Pilz is a standalone system for monitoring emergency stop functions and safety doors in industrial applications. It serves as a central safety component in control systems to ensure the operational safety of machines and plants. The device features integrated screw terminals and is designed for an operating voltage of 24 V DC. It enables 1- or 2-channel wiring of the inputs, with optional cross-connection detection to prevent false alarms caused by accidental connections.
Applications
The device is specifically designed for integration into safety-critical installations, particularly in the manufacturing industry, for machines with emergency stop switches or safety doors. Monitoring is performed via the inputs, which are connected to safety contacts such as emergency stop buttons or door contacts. The outputs enable control of safety functions such as disconnection of drives, disconnection of power supplies, or activation of warning signals. The reset delay of the outputs ensures that the machine is not immediately reactivated after opening a safety door, thereby increasing operational safety.
Functions and Equipment in Detail
The device features three safety-oriented (S) and two safety-oriented, reset-delayed (Sz) outputs. The reset-delayed outputs are particularly important to ensure that after opening a safety door or actuating an emergency stop switch, the machine cannot be immediately reactivated. The reset time is adjustable in 12 steps, from 0.1 seconds to 30 seconds, allowing adaptation to different requirements in production. The inputs support both 1- and 2-channel wiring, with optional cross-connection detection to detect errors caused by accidental connections.
Technology Explained Simply
The safety control device operates as a standalone system, meaning it does not require additional control or monitoring by a higher-level system. The integrated screw terminals enable quick and secure wiring. The operating voltage of 24 V DC is widely used in industrial electronics and ensures reliable power supply. The reset delay of the outputs is implemented via an internal timing circuit, which keeps the outputs active for the set duration after an input is opened (e.g., a safety door), before they reset. This prevents the machine from being immediately reactivated after opening, which could pose a hazard in some installations.
Compatibility and Accessories
The device is compatible with the protective cap P-93(V, available as an accessory. This cap provides mechanical protection reinforcement and can be used to prevent accidental contact or to improve mechanical stability. The use of the protective cap is optional and depends on the specific requirements of the installation.
Mounting and Installation
The device is installed in standard DIN rail mounting, with the integrated screw terminals enabling direct connection to safety contacts and control wiring. Mounting takes place in an enclosure or control box designed according to safety regulations. Wiring is carried out according to the manufacturer’s technical instructions, ensuring correct assignment of inputs and outputs. The reset time is set via an adjustment feature on the device, which can be selected between 0.1 and 30 seconds depending on application requirements.
Advantages in Operation
The safety control device offers high reliability through its standalone function and integrated cross-connection detection. The adjustable reset time allows flexible adaptation to different plant conditions. The integrated screw terminals reduce installation time and increase connection security. The use of 24 V DC as operating voltage ensures high compatibility with existing systems. The outputs are clearly structured into safety-oriented (S) and reset-delayed (Sz) contacts, simplifying planning and maintenance of the installation.