| General |
| Device type | safety switchgear |
| Operating voltage | 24 V DC |
| Inputs | 1/2-channel wiring with/without cross-connection detection |
| Outputs | 2 S, 2 Sz |
| Clamps | Integrated screw terminals |
| Function | Monitoring of emergency stop, safety doors |
| Release-delay | 2 delayed return contacts |
| Delay time | adjustable in 12 steps from 0.1 - 3 s |
The safety control device PNOZXV2-3S from Pilz is a standalone system for safe control and monitoring in industrial applications. It is used for monitoring emergency stop functions and safety doors in machines and plants. The device is designed for use in safety-critical environments and enables 1- or 2-channel wiring of the inputs, with cross-connection detection optionally activated or deactivated. The outputs consist of two safe contacts (2 S) and two additional safe contacts (2 Sz), suitable for controlling drives, motors, or other safety-relevant components.
Applications
This device is used in industrial automation, particularly in machine building, packaging technology, material handling, and other areas where the safety of operators and equipment is paramount. It monitors the function of emergency stop switches and safety doors to safely shut down the machine in case of failure or unauthorized access. The integrated delayed-release contacts enable controlled shutdown, which may be necessary depending on the application to avoid mechanical stress or to ensure moving parts come to a complete stop.
Functions and Equipment in Detail
The safety control device features integrated screw terminals, enabling direct and secure connection of wiring. The operating voltage is 24 V DC, which is a standard value in industrial electronics and ensures reliable power supply. The device width is 45 mm, making it suitable for installation in standard control panels. The delay time of the delayed-release contacts is adjustable in 12 steps, ranging from 0.1 seconds to 3 seconds. This adjustability allows adaptation to specific machine requirements, such as avoiding mechanical shocks or ensuring complete stoppage of moving parts.
Technology Explained Simply
The 1- or 2-channel wiring of the inputs allows flexible integration into existing safety architectures. With 2-channel wiring, safety is enhanced through redundant signals, so a fault in one channel does not cause malfunction. Cross-connection detection identifies if a cable between two inputs has been severed, providing an additional safety feature. The outputs 2 S and 2 Sz are designed for safe switching operations, with the delayed-release contacts enabling controlled shutdown. The delay time is adjusted via a rotary knob, allowing individual adjustment of the contact release time.
Compatibility and Accessories
The device is compatible with accessory item 774090 protective cap P-93(V), which can serve as additional protection for control elements or as an identification feature. Compatibility with other Pilz products is ensured, especially in systems based on the PNOZ platform.
Mounting and Installation
The device is mounted in standard control panels with a width of 45 mm. The integrated screw terminals simplify wiring, which must be carried out according to the technical requirements of safety standards. Installation requires knowledge of industrial electrical engineering and should be performed by qualified personnel in accordance with applicable regulations.
Advantages in Operation
The combination of flexible wiring, adjustable delay time, and integrated screw terminals offers high adaptability to different applications. The delayed-release contacts increase operational safety, especially in plants with moving parts. The 24 V DC operating voltage is widely used and enables easy integration into existing systems. The compact design with a width of 45 mm saves space in the control panel and simplifies planning of safety architectures.