| General |
| Device type | safety switchgear |
| Operating voltage | -24 V DC |
| Inputs | 1/2-channel wiring without short-circuit detection |
| Outputs | 3 S, 1 Ö, 2 Sz |
| Release-delay | two independently adjustable contacts |
| Delay stages | 12 stages |
| Delay times | 1–20 s and 0.1–3 s |
| Clamps | Integrated screw terminals |
| Monitoring functions | emergency stop, safety doors, return circuit |
| Type of device | Standalone |
The safety control device PNOZ2VJ24VDC3N/O1N/C2N/OT from Pilz is a standalone system for safe control and monitoring in industrial applications. It is used for monitoring emergency stop switches, safety doors, and feedback circuits to ensure the safety of machines and plants. The device is designed for use in environments with increased safety requirements and enables the safe shutdown of drives or processes upon detection of a hazardous condition. The operating voltage is -24 V DC, indicating the Japanese voltage polarity and relevant for applications in Japan or systems with corresponding voltage polarity.
Safety control device
The device features a 1/2-channel configuration without cross-circuit detection, meaning it is designed to process safety signals from one or two channels without detecting a cross-circuit between the channels. The outputs include three safety outputs (S), one normally open contact (O), two safety auxiliary outputs (Sz), and two delayed reset contacts. These outputs enable the control of various loads, such as drives, light signals, or auxiliary functions, while providing the necessary safety function.
Functions and equipment in detail
A central feature of the device is the two independently adjustable delayed reset contacts. These allow for a time-delayed reset of the outputs after a triggering event, ensuring, for example, a safe cooldown phase for mechanical systems or a delay during restart. The delay times are adjustable in 12 steps, with values ranging from 1 to 20 seconds and from 0.1 to 3 seconds. This flexibility allows adaptation to different process requirements. The integrated screw terminals simplify installation and maintenance, as no additional terminals or adapters are required.
Technology explained clearly
The device operates as a standalone safety control device, meaning it functions independently of a higher-level control system and is directly integrated into the safety chain. The monitoring functions include control of emergency stop switches, ensuring an immediate stop upon activation, and monitoring of safety doors, which shut down the machine when opened. The feedback circuit is also monitored to ensure the safety function's feedback is correct. The operating voltage of -24 V DC is a specific configuration commonly used in certain markets, particularly in Japan.
Compatibility and accessories
The device is designed for use in industrial safety systems and can be combined with various sensors, switches, and loads connected to its inputs and outputs. The integrated screw terminals allow for direct connection to standard cables and wiring.
Mounting and installation
Mounting is done in a standard control cabinet or enclosure construction. The device width is 112.5 mm, making it suitable for installation in standard control panels. The integrated screw terminals simplify wiring, and the device front is designed to fit into existing installations.
Advantages in operation
The combination of multiple safety outputs, delayed reset contacts, and the option for 1/2-channel configuration provides a flexible and reliable safety function. The adjustable delay times allow adaptation to specific process requirements, increasing operational safety. The integrated screw terminals reduce installation time and improve connection reliability. The device is designed for use in industrial environments where high availability and safety are required.