| General |
| Operating voltage | 24 V DC |
| Number of safety outputs | 2 |
| Number of standard outputs | 1 |
| Terminal type | pluggable spring force terminals |
| Product type | contact extension |
| Compatibility | PNOZsigma safety devices, safety-oriented control components |
The PNOZsigma contact extension from Pilz is an expansion module for safety-oriented control components, specifically developed for integration into existing safety architectures. The device serves to extend the number of available safety outputs and enables the control of additional loads in industrial environments. It is designed for operating voltages of 24 V DC and features a modular design with a width of 22.5 mm, making it suitable for use in standard DIN control panels. The contact extension is equipped with plug-in spring-cage terminals, enabling quick and secure connection of cables.
Applications
The contact extension is used in systems where the number of safety outputs from the main controller is insufficient to switch all required loads. Typical applications include machines with multiple emergency stop switches, safety doors, drives, or other safety-relevant components that must be controlled via separate safety outputs. The module is designed for use in industrial environments where high reliability and mechanical robustness are required.
Functions and Equipment in Detail
The device features two HL safety outputs and one standard HL output. The HL safety outputs are designed for controlling safety-relevant loads and meet the requirements for safety-oriented switching functions. The standard HL output can be used for non-safety-critical loads. The outputs are designed to be operated in conjunction with a PNOZsigma safety device or other safety-oriented control components. The plug-in spring-cage terminals allow for quick installation and maintenance without additional tools.
Technology Explained Simply
The contact extension operates as a passive module without its own logic or control functions. It is directly connected to an existing safety device and handles signal transmission from that device to the connected loads. The operating voltage of 24 V DC is supplied by the main controller. The switching functions of the outputs occur synchronously with the controller, ensuring consistent and secure signal transmission. The spring-cage terminals ensure a reliable electrical connection, even under vibration or mechanical stress.
Compatibility and Accessories
The module is specifically designed for use with PNOZsigma safety devices and other safety-oriented control components from Pilz. It can be combined with compatible accessories such as the PNOZ s Set with spring loaded terminals (St=VE with 4 terminals) or the PNOZ S Terminator Plug (10 pieces) to optimize wiring. Additionally, a PNOZ s plug connector VE=10 pieces is available, which simplifies connections between modules. Compatibility with other manufacturers is not explicitly stated.
Mounting and Installation
Mounting is performed in standard DIN control panels. The module is connected to the respective cables using the integrated spring-cage terminals. Wiring must follow the technical instructions of the respective control unit. Installation requires no special tools, as the terminals are plug-in. Correct cable arrangement and adherence to circuit diagrams are essential for functional safety.
Advantages in Operation
The contact extension enables flexible expansion of safety outputs without replacing the main controller. The modular design and plug-in terminals reduce installation time and simplify maintenance. Use in conjunction with PNOZsigma systems ensures high compatibility and reliability. The outputs are designed for use in safety-critical applications, thereby increasing the overall safety of the system.