JUNG NRSAS0834USVWW USV module Series A/AS alpine white

Installation > Switch Material > Switch flush surface

JUNG NRSAS0834USVWW USV module Series A/AS alpine white

Lieske Part No. 532698
Mfg Part No NRSAS0834USVWW
EAN-Code 4011377130746
Manufacturer JUNG
Here only 262,61 EUR
312,51 EUR incl. VAT

Further information for JUNG NRSAS0834USVWW USV module Series A/AS alpine white

General
Input voltage24 V DC
Output voltage in battery operation22,8 V DC
Output voltage tolerance±10 %
Rated load in battery operation130 mA
Operating time at rated load1 Hour
Maximum load in battery operation300 mA
Maximum operating time in battery operation15 minutes
Maximum load in mains operation250 mA
Mounting methodScrew mounting
Mounting clawsNone
FrameNone
Colouralpine white
CompatibilityPower supply NRS .. 0834 NT ..
The JUNG NRSAS0834USVWW is a flush-mounted emergency call module with integrated UPS function, specifically designed for use in safety and emergency call systems. It serves to bridge power outages in the power supply unit, ensuring the functionality of critical systems is maintained even during a power failure. The module is delivered without a frame and is available in alpine white. Installation is carried out via screw fastening, with no mounting claws provided. For secure installation, it is recommended to use a deep back box to fully accommodate the module body.

Applications

The module is intended for use in emergency call systems, particularly in buildings with increased requirements for the availability of safety functions. It is operated in conjunction with a power supply unit from the NRS series (part no. NRS .. 0834 NT ..), which provides an input voltage of DC 24 V. The UPS function ensures that in the event of a mains power failure, the supply to connected components is temporarily maintained, preventing interruption of critical functions such as alarm transmission or emergency call connection.

Functions and Equipment in Detail

The module supplies power via an integrated battery pack, which is automatically activated when the mains voltage is interrupted. The output voltage during battery operation is DC 22.8 V with a tolerance of ±10 %. This voltage is sufficient to continue operating connected devices in an emergency. The rated load is 130 mA and can be drawn for a duration of one hour during battery operation. For short-term load peaks, a maximum load of 300 mA for 15 minutes is possible. In mains operation, the module can deliver a maximum load of 250 mA.

Technology Explained Simply

The integrated UPS function enables a seamless transfer of power supply from the mains to the internal battery. This occurs automatically, without requiring additional switching operations. The voltage values are designed to cover the operating voltage of most emergency call components. The ±10 % tolerance on output voltage during battery operation is sufficient for most applications, as emergency call systems often allow for some voltage tolerance. The specification of load values (rated and maximum) enables targeted sizing of connected loads to optimize operating time during battery operation.

Compatibility and Accessories

The module is specifically designed for use with power supplies from the NRS series (part no. NRS .. 0834 NT ..). The input voltage of DC 24 V must be supplied by this power supply unit. It is not designed for other voltage sources. Installation is carried out in a flush-mounted back box, requiring a sufficiently deep box to fully accommodate the module.

Installation and Mounting

Installation is performed by screw fastening into a flush-mounted back box. Since no mounting claws are provided, precise alignment and secure fastening using screws is required. The back box must be sufficiently deep to fully accommodate the module, ensuring a secure and stable installation. Wiring is carried out via the designated terminal clamps, intended for connection to the power supply unit and connected devices.

Operational Advantages

The integrated UPS function provides reliable power supply for emergency call systems, even during short-term power outages. The automatic transfer from mains to battery operation occurs without interruption, ensuring the functionality of connected devices. The defined load values enable precise planning of system loads to maximize operating time during battery operation. Use in conjunction with a power supply unit from the NRS series ensures a compatible and reliable system environment.