Accuracy / Deviations
Repeatability± 5 mm
Measurement error± 7 mm
Offset error5 mm
Resolution1 mm
Temperature influence per 10 K± 0,2 %
Approvals / tests
ApprovalWHG; General building authority approval; Overfill protection
EMCDIN EN 61000-6-2; DIN EN 61000-6-3 / in closed metal enclosure; DIN EN 61000-6-4 / in plastic or open metal enclosure
Shock resistanceDIN EN 60068-2-27 / 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
Vibration resistanceDIN EN 60068-2-6 / 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference bar 0.5 m
MTTF198 years
Displays / controls
IndicationDisplay unit / 3 x LED, green; Switching state / 4 x LED, yellow; Fill level / alphanumeric display, 4-digit; Parameter setting / alphanumeric display, 4-digit
Electrical connection
Plug connection1 x M12; Coding: A; Contacts: 7, gold-plated
Electrical data
Operating voltage18...30 DC V
Electricity consumption< 30 mA
Protection classIII
Standby delay time< 3 s
Measurement principleGuided microwave
Reverse polarity protectionYes
Environmental conditions
Ambient temperature0...60 °C
Storage temperature-25...80 °C
Degree of protectionIP 67
Field of application
Special featureGold-plated contacts
Applicationfor industrial use
MountingOperate only in combination with probe rod and coaxial tube
Medialiquid media
Dielectric constant of medium≥ 2
Recommended mediaWater; water-based media; water-based coolant lubricants; oils; oil-based media
Not suitable forSee instruction manual, chapter "Intended use".
Process temperature0...80; (see note under Remarks) °C
Compressive strength4 bar / 0.4 MPa
Vacuum tightness-500 mbar / -0.05 MPa
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38.4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
Required master port classA
Analog process data1
Process data binary4
Min. process cycle time2,3 ms
Supported DeviceIDsOperating mode / DeviceID; default / 1250
SIO modeYes
Measurement / adjustment range
Active area AL-40; (when set to oil and oil-based media: L-60) mm
Inactive zone I1 / I230 / 10; (at setting for oil and oil-based media: 30 / 30) mm
Measurement frequency4 Hz
Switching point SP15...L-30 mm
Switching point SP notewhen set to oil and oil-based media: 35...L-30
Reverse switch point rP10... L-35 mm
Note on reverse switching point rPwhen set to oil and oil-based media: 30...L-35
In steps of5 mm
Hysteresis> 5 mm
Overfill switch point OP70...L-30 mm
Hysteresis OP10 mm
Mechanical data
DimensionsØ 50 / L = 99 mm
Materials1.4404 (stainless steel / 316L); 1.4301 (stainless steel / 304); FKM; PBT; PC; PEI; TPE-V
Materials in contact with the mediumSensor:: 1.4305 (stainless steel / 303); 1.4435 (stainless steel / 316L); PTFE; FKM; NBR reinforced; Probe rod:: 1.4404 (stainless steel / 316L); Coaxial tube:: 1.4301 (stainless steel / 304); 1.4404 (stainless steel / 316L); 1.4310 (stainless steel / 301); PPS reinforced
Outputs
Total number of outputs4
Output signalSwitching signal
Electrical versionPNP
Number of digital outputs4
Output functionNormally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC2,5 V
Continuous current rating of switching output DC200 mA
Short-circuit protection typethermal, timed
Short-circuit protectionYes
Overload resistantYes
Product features
Number of inputs and outputsNumber of digital outputs: 4
Rod length L100...1600 mm
Process connectionthreaded connection G 3/4 male thread
Remarks
NotesFor high process temperatures: The relevant temperature is at the process connection. The actual medium temperature may be higher.
Electronic level sensor, DC PNP, Guided wave radar, Freely rotatable housing 360°, General building authority approval: Z-65.16-529, Overflow protection, Only use with a rod + a coaxial pipe, Connector, 4-digit alphanumeric display, 4 switching outputs (one of them for overflow protection according to the German Federal Water Act (WHG)), 4-digit alphanumeric display
Application: Hydrous coolants, oils, oil-based media, water, media similar to water
Operating voltage: 18...30 V DC
Electrical design: DC PNP
Output function: 3 x NO / NC programmable;, 1 x NC (WHG - German Federal Water Act)
Current rating: 200 mA
Probe length L: 100...1600 mm
Active range A: L-40 (L-60) mm
Connection: M12 connector (according to EN 61076-2-101)
Housing materials: stainless steel 316L / 1.4404; stainless steel (304S15); FKM; PBT-GF 20; PC; PEI; TPV
Materials (wetted parts): stainless steel (303S22); probe connection: stainless steel 316L / 1.4435; PTFE; FKM; sealing: NBR-PPTA 20
Medium temperature: 0...80 °C
Ambient temperature: 0...60 °C
Protection: IP 67
Display: Display unit: 3 x LED green ; Switching status: 4 x LED yellow ; Level: 4-digit alphanumeric display ; Programming: 4-digit alphanumeric display
Accessories (to be ordered separately): Socket, Mounting accessories