Hager ADX466D, EAN: 3250611017042

Hager ADX466D RCD 4P 16A 30mA

Installation > Modular devices / equipment installation > Circuit breaker

Hager ADX466D RCD 4P 16A 30mA

Lieske Part No. 145534
Mfg Part No ADX466D
EAN-Code 3250611017042
Manufacturer Hager
Here only 284,81 EUR
338,92 EUR incl. VAT

Further information for Hager ADX466D RCD 4P 16A 30mA

General
Number of poles (total)4
Number of protected poles4
Rated voltage400 V
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV
Rated current16 A
Rated fault current0.03 A
Leakage current typeA
Current limiting class3
Rated short-circuit breaking capacity Icn acc. EN 61009-110 kA
Disconnection characteristicUndelayed
Surge current capacity3 kA
Voltage typeAC
Frequency50 Hz
Release characteristicC
Over voltage category3
Pollution degree2
Ambient temperature during operating40 °C
Width in number of modular spacings4
Built-in depth70 mm
Degree of protection (IP)IP2X
Connectable conductor cross section solid-core25 mm²
Connectable conductor cross section multi-wired16 mm²
Power loss10.9 W
Concurrently switching N-neutralyes
With interlocking deviceyes
Anti-nuisance tripping versionno
The Hager residual current circuit breaker ADX466D is a 4-pole switch with a rated current of 16 A and a rated residual current of 30 mA. It is designed to protect electrical installations against overloads and dangerous fault currents, particularly in residential and commercial applications. The switch combines overload protection (circuit protection) with protection against dangerous fault currents (residual current protection) in a single device. It is designed for 400 V AC voltage and offers a rated short-circuit breaking capacity of 10 kA, making it suitable for demanding applications. The C tripping characteristic ensures targeted response to overloads, while the residual current type A also detects pulsating fault currents, such as those generated by electronic devices or LED lighting.

Applications

The ADX466D is designed for use in 400 V three-phase networks, particularly in residential and commercial installations where high safety against electrical hazards is required. It protects people from electric shocks and prevents fires caused by overloaded cables. The combination of residual current and overload protection in a single device reduces the number of required components and simplifies installation. The protection class IP2X ensures protection against contact with solid objects and access to hazardous parts, but not against water or dust. The operating temperature is up to 40 °C, making it suitable for indoor use.

Functions and Equipment in Detail

The switch features a switching neutral conductor, meaning that when all phases are switched off, the neutral conductor is also interrupted. This is important to ensure safe disconnection of the power supply. The locking device enables secure mounting and locking in the enclosure. The energy limitation class 3 ensures limited energy release in the event of a fault, reducing the risk of thermal damage. The switch is equipped with a blue test button to check the residual current protection function. The residual current protection status is directly visible on the device.

Technology Explained Simply

The switch operates on the principle of residual current protection: it monitors the current flow in the conductors and trips when an imbalance between incoming and outgoing current is detected, indicating a fault current. The C tripping characteristic means the switch trips at a current of approximately 5 to 10 times the rated current (i.e., 80 to 160 A), which is typical for overloads. The rated voltage of 400 V and the rated insulation voltage of 500 V ensure safe operation in standard networks. The impulse voltage withstand of 4 kV protects the device against transient voltage surges. The power loss is 10.9 W, describing the heat generation during operation.

Compatibility and Accessories

The ADX466D is designed for installation in standard installation enclosures and has a width of 4 module units. It is compatible with various cable bridges, such as the K67E (6 mm², 250 mm) or K67L (10 mm², 250 mm, fork). Additionally, auxiliary and signaling contacts such as MZ201 or MZ202 can be used to implement additional functions such as status indication or remote control. The spacing piece LZ060 can be used for heat dissipation to reduce thermal load in the enclosure.

Mounting and Installation

The switch is mounted in a modular enclosure, with the lower connection terminal designed for the biconnect system. The connection cross-sections are up to 16 mm² for flexible conductors and up to 25 mm² for single-core conductors. The nominal torque is 2 Nm for both terminals. The mounting depth is 70 mm, which must be considered during enclosure planning. Mounting is done by simply snapping into the phase busbar, allowing individual removal.

Advantages in Operation

The ADX466D offers a compact and efficient solution for protecting electrical installations. The combination of residual current and overload protection in a single device reduces the number of required components and simplifies installation. The locking device and switching neutral conductor increase safety. Compatibility with various accessories allows flexible adaptation to specific requirements. The clear indication and test button facilitate maintenance and testing of the device. The service life is 2000 electrical and 4000 mechanical switching operations, ensuring high operational reliability.