Further information for Gira 540300 Relay Switch Module S3000
General
Assembly arrangement
Basic element
Type of load
Universal
Mounting method
Flush mounted (plaster)
Material
Other
Material quality
Other
Surface protection
Other
Colour
Other
Nominal voltage
230 V
Frequency
60 Hz
Rated current
16 A
Type of fastening
Mounting with claw and screw
Min. depth of built-in installation box
32 mm
Number of channels
1
Substation input
Light value memory
Applicable with button
Applicable with movement sensor
Applicable with presence indicator
Applicable with time switch/timer
Applicable with transmission button
Applicable with infrared button
Transparent
IFTTT support available
System 3000 relay switching insert - Switching of lighting and single-phase motors. - Control of electric underfloor heating and thermal actuators in combination with a room temperature controller attachment. - Adaptive zero point switching. - Connection of extensions possible. - Automatic switching off of the load. Run-on times adjustable in five stages, cannot be retriggered. - Test operation for functional testing. - Operation with neutral conductor connection. Combination with RF operating attachment 1-way / 2-way for KNX: - Switching actuator channel 1-way or heating actuator 1-way - Sensor channel 1-way or 2-way. - Local control of the System 3000 insert possible. - Radio control of other devices for KNX as a sensor possible. - Temperature detection. - {b}Function selection of the insert for switching:{\b} Normally open/normally closed operation, staircase function with switch-off warning, scene function (16 scenes), lock function, time delays. Extension input as an additional control point for the System 3000 insert or for radio control of other devices for KNX as a sensor possible. - {b}Function selection of the insert for room temperature controller:{\b} Control of 230 V actuators, heating, cooling mode, heating and cooling mode, switching of heating or cooling mode via communication object or extension input. PWM and 2-point controller, absolute and relative setpoint specification, heat requirement control including cascading, valve protection function. Cyclic monitoring of the floor temperature, service mode for valve output, frost protection function (automatic or via communication object), calibration of the temperature sensor, boost function, summer and winter compensation, scene function (16 scenes). If the ambient temperature is higher than 35 °C, the connected load must be reduced.