| General |
| Compatibility | smoke detector Dual Q, Dual/VdS |
| Functions | alarm, substation alarm, wired alarm, signal transmitter, status messages, fault messages |
| KNX medium | TP256 |
| Connection | connection and branch terminal for KNX |
| Ambient temperature | -5 °C |
The Gira KNX module for smoke detector Dual (type 234300) is a specific interface module for integrating the smoke detector Dual Q into a KNX system. It enables bidirectional communication between the smoke detector and the building automation, allowing alarm and status messages to be transmitted over the KNX network. The module is downward compatible and can therefore also be used with smoke detectors Dual/VdS, increasing flexibility in system planning.
Applications
The module is primarily intended for networking smoke detectors in intelligent building systems. It is used in residential and commercial buildings where central monitoring and control of security systems via KNX is required. Integration into existing KNX infrastructures enables central alarm processing, which can be extended with auxiliary station alarms and wired alarm connections.
Functions and equipment in detail
The module performs the function of a signal generator, which can activate the alarm tone of the smoke detector. It supports alarm notifications, auxiliary station alarms (for networking multiple smoke detectors via KNX) as well as wired alarm connections, where the message is transmitted via a separate line between the devices. In addition, status and fault messages are transmitted to make the operating status of the smoke detector visible within the KNX system. The networking terminals of the smoke detector remain usable even after inserting the module, simplifying installation and maintenance.
Technology explained simply
The module connects directly to the interface of the smoke detector Dual without additional mounting or drilling. It uses the KNX transmission medium TP256, which is standardized for data transmission in building automation systems. The connection and branch terminal for KNX is included in the delivery scope and enables easy integration into existing KNX lines. The ambient temperature range in which the module can be operated is between -5 °C and +50 °C, ensuring use in indoor environments under normal operating conditions.
Compatibility and accessories
The module is specifically developed for the smoke detector Dual Q, but due to downward compatibility, it is also compatible with smoke detectors Dual/VdS. Suitable accessories offered in the product line include the smoke detector Dual Q pure white (article number 233602), which can be directly connected to the module. Networking is done via the KNX network, with functions such as alarm, status, and fault messages being transmitted through the system.
Mounting and installation
Mounting is done by simply plugging the module onto the interface of the smoke detector. No additional mounting or drilling is required. The networking terminals of the smoke detector remain available, allowing a parallel wired alarm connection to be implemented. Planning guidelines are available in the brochure Technical Information, which can be downloaded from the website www.download.gira.de.
Advantages in operation
Integrating the smoke detector into a KNX system enables central monitoring and control. Alarms can be transmitted to multiple auxiliary stations, increasing responsiveness in emergencies. The signal generator function allows the alarm tone of the smoke detector to be activated via the KNX system, which is useful for alerting people in buildings. Status and fault messages support maintenance and inspection of the system, as the operating status can be checked at any time within the system.