Further information for Gira 213900 Heating Actuator 6f Regulator OneK
General
Other bus systems
Other
Mounting method
DRA (DIN-rail adapter)
Width in number of modular spacings
4
Number of outputs
6
Max. output current
160 A
Switching voltage
230 V
Degree of protection (IP)
IP20
Bus system KNX
Bus system KNX radio
Bus system radio frequent
Bus system LON
Bus system Powernet
Radio frequent bidirectional
Bus connection included
Bus module detachable
Correcting variable consistent
Correcting variable switching
Valve protection function
Manual switch
6-way heating actuator with controller for Gira One and KNX - Heating actuator with integrated room temperature controller for controlling electrothermal actuators for heating and cooling systems. Valve outputs: - 6 independent electronic valve outputs. - Valve output 1 can be used as a template for other valve outputs. - Message of the largest manipulated variable of the actuator can be parameterized. - Actuators with a nominal voltage of 24 V or 230 V can be controlled. - Valve control (open / closed when de-energized) can be parameterized for each output. - Actuated variable input: switching - 1 bit" and "continuous - 1 byte". - Valve control: "switching - 1 bit", "continuous - 1 byte PWM" or "continuous - 1 byte manipulated variable limit value". - Status feedback can be configured. - Failure message of the valve operating voltage can be configured. - Overload and short-circuit messages can be set separately for each valve output. - Heat demand and pump control. Anti-jamming protection prevents the pump from jamming. - Summer or winter operation can be selected via an object. - Each valve output can be locked in a forced position. Different control value values can be parameterized for summer and winter operation. - Cyclic monitoring of the control value of each output. - Automatic valve flushing. - Operating hour counter can be configured for each output. - Service operation for maintenance or installation of valve drives. - Manual operation of the outputs independent of the KNX. - Reactions to bus voltage failure and return and after an ETS programming process can be set for each valve output. - Various actively sending status messages can be globally delayed after bus voltage return or after an ETS programming process. Room temperature controller: - 12 independent room temperature controllers. - Room temperature controller 1 can be used as a template for other room temperature controllers. - Operating modes: Comfort, standby, night and frost/heat protection. - Each operating mode can be assigned its own temperature setpoints. - Setpoint temperature specification: relative (derived from the basic setpoint) or absolute (independent setpoint temperatures for each operating mode). - Presence detection via presence button or presence detector. - Switching of operating modes according to KNX specification. - Status feedback can be configured. - Frost/heat protection switching via window status or temperature drop detection. - Operating modes: "Heating", "Cooling", "Heating and Cooling", each with or without additional stage. - Different control types can be configured for each heating or cooling stage: PI control (continuous or switching PWM) or 2-point control (switching). - Different types of heating and cooling can be set. - Control parameters for PI controllers (proportional range, reset time) and 2-point controllers (hysteresis) can be set.- Automatic or object-oriented switching between "heating" and "cooling. - The control variable outputs can be blocked using objects. - Room temperature measurement using up to two external KNX temperature sensors. Measurement value generation of the external sensors can be parameterized or monitored cyclically. - The actual and target temperatures can be output to the bus (also cyclically) after a parameterized deviation. - Separate or joint control variable output in heating and cooling mode (4-pipe or 2-pipe system). - Automatic sending and cycle time for control variable output can be parameterized. - Control variable limitation possible. - Floor temperature limitation possible in heating and cooling mode. - Target temperature limitation possible in cooling mode. - Target temperature increase possible in heating mode. - Boost function for rapid heating or cooling. - Scenes: Up to 64 internal scenes can be parameterized per controller. Incl. scene storage function and extended scene recall (toggling of scenes). Logic functions: - The device has 8 internal logic functions. - Lo