Faber Kabel 0113080400000, EAN: 4035996023340

Faber Kabel 0113080400000 NA2XS(F)2Y 1X240/25 12/20 kV SW earth cable

Cables > Underground cables > Medium Voltage Underground Cables N2XSY

Faber Kabel 0113080400000 NA2XS(F)2Y 1X240/25 12/20 kV SW earth cable

Lieske Part No. 925431
Mfg Part No 0113080400000
EAN-Code 4035996023340
Manufacturer Faber Kabel
Here only 38,39 EUR
45,68 EUR incl. VAT

Further information for Faber Kabel 0113080400000 NA2XS(F)2Y 1X240/25 12/20 kV SW earth cable

General
Cable typeNA2XS(F)2Y
Conductor cross section240 mm²
Protective conductor cross-section25 mm²
Voltage class12/20 kV
Material outer sheathPE
Installation methodin ground, in water, outdoors, indoors, in cable channels
ApplicationsEVU networks, industry, distribution networks
Flame retardancyNot flame retardant (PE sheath according to DIN VDE 0482-332-1)
Length shapeCut length
The product is a medium-voltage underground cable of the brand Faber Kabel, type NA2XS(F)2Y 1X240/25 12/20 KV SW, specifically designed for use in power networks. It is intended for power transmission in utility networks (EVU), industrial facilities, and distribution networks, and is suitable for installation in earth, water, outdoors, indoor spaces, and cable ducts. The cable features high mechanical and chemical resistance, making it particularly suitable for challenging operating conditions where water ingress along the length must be prevented after mechanical damage. The construction with a PE sheath enables effective sealing, ensuring functionality is maintained even if the outer sheath is damaged.

Applications
This cable is intended for use in underground installations, underwater, outdoors, as well as in indoor spaces and cable ducts. It is used in power networks of electricity utilities (EVU), in industrial applications, and in distribution networks. Installation in cable ducts and indoor spaces requires special attention, as the PE sheath is not flame-retardant according to DIN VDE 0482-332-1. This means that additional protective measures may be required in case of fire hazards to ensure safety.

Functions and Equipment in Detail
The cable features a cross-sectional area of 240 mm² for the conductor and 25 mm² for the protective conductor. The designation 1X240/25 indicates that this is a single-core cable, with the main conductor being 240 mm² and the protective conductor 25 mm². The voltage class 12/20 kV defines the maximum operating voltage and test voltage, where 12 kV is the operating voltage and 20 kV is the test voltage. The designation SW (steel helix) indicates reinforcement of the cable with a steel helix, providing enhanced mechanical stability and protective function.

Technology Explained Simply
The designation NA2XS(F)2Y describes the cable’s construction: N stands for non-flammable, A for aluminium, 2X for two conductors, S for protective conductor, (F) for the use of fibre or fibre reinforcement, 2Y for two layers of polyethylene (PE). The cable is equipped with a PE sheath, which offers high chemical resistance and good insulation properties. The steel helix (SW) provides additional mechanical protection and prevents water ingress along the length, which is particularly important in case of mechanical damage. The use of PE as sheath material is suitable for outdoor and underground installations, as it is UV-resistant and durable against environmental influences.

Compatibility and Accessories
The cable is suitable for use in existing and new distribution networks and can be connected with standard connectors and termination components. It is designed for installation in various environments, with specific installation and environmental requirements to be observed. Use in indoor spaces and cable ducts requires consideration of the non-flame-retardant properties of the PE sheath to comply with safety regulations.

Installation and Mounting
Installation is typically carried out by professional electricians. Installation in earth, water, or outdoors requires compliance with applicable standards and regulations. When installing indoors or in cable ducts, the non-flame-retardant property of the PE sheath must be taken into account to meet fire protection requirements. The cut length allows flexible adaptation to specific installation requirements.

Operational Advantages
The cable offers high reliability and long service life, especially in demanding environments. The steel helix prevents water ingress along the length, ensuring functionality even after mechanical damage. The high mechanical stability and chemical resistance of the PE sheath contribute to a long service life and low maintenance costs. Its use in EVU networks, industry, and distribution networks demonstrates suitability for critical applications where high safety and reliability are required.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111