Further information for Eltako 23200901 S2U12DDX-UC 2-channel timer digital
General
Number of channels
2
Switching type
normally open contact (NO), potential-free
Nominal voltage
250 V AC
Nominal current
16 A
Stand-by loss
0,03-0,4 Watt
Gear reserve without battery
7 Days
Storage slots
60
Supply voltage
8-230 V UC
Control input
+A1
Mounting
DIN-EN 60715 TH35
Display backlighting
from production week 26/19
Adjustable languages
German, English, French, Italian, Spanish
Adjustable astro time shift
±2 hours
Adjustable equinox time shift
±2 hours
Pulse switching time
2 seconds
Additional standby loss with DX
0.1 Watt
Astro function
Automatic daylight saving time/winter time switch
Key lock
Bistable relay
Eltao Duplex Technology (DX)
The Eltako S2U12DDX-UC is a digital 2-channel timer switch for use in electrical installations. The device is designed for automatic control of loads via two independent switching channels and is intended for mounting on a support rail in accordance with DIN-EN 60715 TH35. With a width of 18 mm (1 module unit) and a depth of 58 mm, it fits into standard installation enclosures. The timer switch features two potential-free contacts with a rated capacity of 16 A at 250 V AC, suitable for operating lighting, heating, or other electrical loads. A central feature is the Astro-function, which enables switching based on sunrise and sunset, thus enabling light-dependent control. The on- and off-time can be shifted by ±2 hours to accommodate regional or individual requirements. Additionally, a time shift of up to ±2 hours influenced by the solstices can be set, allowing precise adjustment to the respective season.
Functions and equipment in detail
The timer switch offers up to 60 memory slots, which can be flexibly distributed between the two channels. Each memory slot can be assigned either an Astro-function, a fixed on- and off-time, or a pulse switching time (2-second pulse). The clock features automatic daylight saving and standard time adjustment, which occurs without manual intervention. The timekeeping reserve is approximately 7 days without a battery, ensuring that time and programming are retained even during a power failure. Settings are made using the MODE and SET buttons, with an option for button lock to prevent unintended changes. The language can be selected within 10 seconds after connecting the supply voltage (German, English, French, Italian, Spanish). The normal display shows day of the week, time, date, and month.
Technology explained clearly
The timer switch uses the patented Eltako Duplex technology (DX), which allows switching even at potential-free contacts during the zero crossing, provided the N conductor is connected to terminal (N) and the L conductor to 1(L) and/or 3(L). This significantly reduces mechanical wear on the contacts. The use of bistable relays ensures that no coil power loss occurs in the switched-on state, minimizing heating. The standby power loss is between 0.03 and 0.4 W, with an additional loss of 0.1 W when using Duplex technology. The supply voltage is 8 to 230 V UC, with the control voltage for central control also within this range. A control input (+A1) enables central control with priority, allowing external systems to override the timer switch.
Compatibility and accessories
The device is designed for use in electrical installations and can be combined with other devices from the Eltako product family, particularly in systems requiring central control via control inputs. The Astro-function requires input of the location (latitude, longitude, time zone), with a list of German cities included in the instruction manual. The timer switch is intended for indoor use, with mounting on a DIN rail. The connection terminals are designed for wire connections, with exact terminal assignment described in the instruction manual.
Mounting and installation
Mounting is done on a support rail in accordance with DIN-EN 60715 TH35. The timer switch is inserted into the rail and secured with the screw clamp. The connection terminals are clearly labeled: (N) for the neutral conductor, 1(L) and 3(L) for the phase conductors. Control is performed using the MODE and SET buttons, with operating steps described in the manual. Setting the time, date, and location is done via menu navigation, with a fast-forward mode activated by holding the input button longer. The display backlight turns on automatically when MODE or SET is pressed and turns off after 20 seconds without operation.
Advantages in operation
The timer switch offers high flexibility through the combination of time- and Astro-control. The Duplex technology and use of bistable relays ensure long service life and low power loss. The automatic daylight saving and standard time adjustment reduces maintenance effort. Central control via the control input enables integration into larger control systems. The 7-day timekeeping reserve without a battery ensures stable function even during power failure. Operation is possible via clear menu navigation, with language selection available individually. The timer switch is suitable for use in residential and commercial buildings, particularly in systems requiring automated lighting or heating control.