Further information for Eltako 22100231 FR12-230V Field Switch 1S
General
Switching power
16 A
Operating voltage
230 V
Degree of protection
not specified
Number of normally open contacts (NO)
1
Switching voltage
250 V
Stand-by loss
0,8 W
Delay time
ca. 1 s
Small consumer threshold
200 mA
Operation mode
self-learning
Technique
Hybrid technology
Switching type
1-pole
Potential-free
non-isolated
LED colour
Red
Compatibility with LED lamps
up to 200 W
Compatibility with incandescent lamps
up to 2300 W
LED indicator
The Eltako FR12-230V is a self-learning field-free switch for installation in electrical distributions. It is designed to interrupt the power supply after switching off downstream consumers, in order to avoid disturbing electromagnetic fields. The device features a 1-pole closer, which is not potential-free, and is designed for an operating voltage of 230 V AC. The maximum switching capacity is 16 A at 250 V AC, enabling use with 230 V LED lamps up to 200 W and incandescent lamps up to 2300 W. The field-free switch operates according to a patented method that automatically learns the threshold value for detecting small consumers, without requiring manual adjustment.
Applications
The FR12-230V is suitable for use in residential and commercial buildings where a reduction of electromagnetic fields in standby mode is required. It is particularly used in rooms with sensitive electronics, such as bedrooms, offices or medical facilities, to minimise the electromagnetic environment. The application is typically carried out in a row-mounted installation in distribution boxes, with the installation being performed by the device itself, without requiring additional components.
Functions and equipment in detail
The switch recognises consumers that, after switching off, consume up to 200 mA as small consumers and does not switch them off, to prevent interruption of the power supply. Consumers with a current consumption exceeding 200 mA are recognised as larger loads and trigger the switching on of the mains voltage. As long as no such consumer is active, the monitored circuit remains 1-pole disconnected from the mains. The neutral and protective conductors are not switched, to avoid an antenna effect. Monitoring is carried out via an adjustable DC voltage with low residual ripple, meaning that bridging the operating contact is not permitted, as this would result in destruction of the device.
Technology explained simply
The hybrid technology of the FR12-230V combines the advantages of a wear-free electronic control with the high switching capacity of a special relay. This ensures reliable and long-lasting operation. The self-learning function enables automatic adaptation to the consumers present in the circuit, without requiring a technician to make manual adjustments. The standby power loss is only 0.8 W, highlighting the energy efficiency of the device. When a consumer is switched on, the field-free switch connects the live conductor with a delay of approximately 1 second, thus avoiding sudden switching on. At the same time, the integrated LED lights up red to indicate the operating status.
Compatibility and accessories
The FR12-230V is designed for use in standard 230 V networks and is compatible with the specified power ratings for LED and incandescent lamps. Installation is carried out without additional tools or components, as the device is designed for direct installation in standard distribution boxes.
Mounting and installation
Mounting is carried out in a row-mounted installation in a distribution box. The electrical connection is made at the designated terminal clamps, with polarity to be observed. The terminal clamps are designed for connection with cables complying with the respective standards. Installation requires no additional tools or components, as the device is designed for direct installation. The terminal clamps are designed to ensure a secure and durable connection.
Advantages in operation
Operation of the FR12-230V is characterised by high reliability and energy efficiency. The self-learning function reduces maintenance effort, as no manual adjustments are required. The low standby power loss of 0.8 W contributes to energy savings. Interrupting the power supply after switching off consumers minimises electromagnetic fields, which is particularly advantageous in sensitive environments. The integrated LED indicator enables visual monitoring of the operating status.