| KNX bus |
| Medium | TP1-256 |
| Configuration mode | S-Mode |
| Maximum group addresses | 183 |
| Maximum assignments | 183 |
| Communication objects | 44 / 55 / 73 |
| Nominal voltage | 30V SELV |
| Electricity consumption | ≤ 10mA |
| Connection KNX plug-in terminal conductor diameter | Ø 0,8mm s |
| Connection KNX plug-in terminal stripping length | 5mm |
| Connection spring clamp wire diameter | Ø 0,8mm s |
| Connection spring clamp stripping length | 7...9mm |
| Time until data reception after bus voltage recovery | ≈ 5 s |
| Sensor |
| Temperature measurement range | 5…+60°C |
| Technical data |
| Housing | Real glass, plastic |
| Colours (similar) | RAL 9003 (white), RAL 9005 (black) |
| Degree of protection | IP20 |
| Dimensions (W × H) | 81,5 mm × 81,5 mm |
| Installation depth | 12,5 mm |
| Weight total | ≈ 70 g |
| Ambient temperature | 5…+45°C |
| rF (relative humidity) non-condensing | 0...95% |
| Storage temperature | 25...+70°C |
| Over voltage category | III |
| Pollution degree | 2 |
The Elsner KNX eTR M2 is a double switch with integrated temperature sensor, specifically designed for integration into KNX building control systems. The device features touch-sensitive switch surfaces made of real glass, serving as touch surfaces to control various functions such as lighting switching, dimming, drive control, or scene calls. Each touch surface is equipped with a white LED, whose operating behavior – such as indication at object value 1, time-controlled illumination after activation, or flashing at lock object value – can be individually configured. The KNX eTR M product series offers various variants, with the M2 model type providing two independent touch surfaces, each of which can be configured as a switch, toggle switch, dimmer, value transmitter, or for scene functions. Additionally, a surface function can be activated, which is triggered by simultaneous touch of both buttons and can also be used as a switch, toggle switch, value transmitter, or scene function.
Applications
The switch is intended for installation in indoor environments where intelligent control of lighting, blinds, roller shutters, or other KNX-compatible devices is required. The integrated temperature measurement enables use in heating and air conditioning control systems, with the sensor covering a measurement range of 5 to +60 °C. The device can receive external temperature values via the KNX bus and combine them with its own measurement value to calculate a mixed value, with the proportion being adjustable in percentage terms. This is particularly useful in rooms where multiple sensors are used for precise temperature detection.
Functions and Equipment in Detail
The two touch surfaces of the eTR M2 can be configured independently. The functions include switching, toggling, dimming, controlling drives such as blinds, roller shutters, or awnings, and operating as an 8- or 16-bit value transmitter. The surface function, activated by simultaneous actuation of both buttons, extends functionality with additional control options. The integrated LED per touch surface can be configured in various operating modes to provide visual feedback. Configuration is performed via the KNX software ETS 5, enabling adaptation to specific requirements in the building automation system.
Technology Explained Simply
The switch operates in S-Mode as a KNX bus device and uses the TP1-256 medium. The nominal voltage is 30 V SELV, with a current consumption of up to 10 mA. Communication objects are available in three variants: 44, 55, or 73, depending on configuration. The maximum number of group addresses and assignments is 183 each. Connections are made via spring-loaded terminals designed for conductors with a diameter of Ø 0.8 mm. The stripping length is 7 to 9 mm for spring-loaded terminals and 5 mm for the KNX plug terminal. After the bus voltage returns, it takes approximately 5 seconds for the device to resume data reception. The devices are designed for an ambient temperature of 5 to +45 °C, with a relative humidity of 0 to 95 %, provided no condensation occurs. Storage is at temperatures of 25 to +70 °C.
Compatibility and Accessories
The device is designed for use in the KNX standard and meets the requirements of overvoltage category III and pollution degree 2. It is equipped with a protection rating of IP20, providing protection against finger contact and solid foreign objects, but not against water or dust. The housing consists of real glass and plastic and is available in the colors RAL 9003 (signal white) and RAL 9005 (black). Dimensions are 81.5 mm × 81.5 mm (width × height), with a mounting depth of 12.5 mm. The total weight is approximately 70 g. The device is delivered with a mounting bracket, 4 plugs (4 × 20 mm), 4 countersunk screws (3 × 25 mm), a KNX terminal, a data sheet with installation instructions (in German, English, French, Italian, Spanish), and a handbook available for download. Additionally, a product file in the mentioned languages is available.
Mounting and Installation
Mounting is done into a standard flush-mounted box. The provided plugs and screws allow for secure fastening. Connections are made via spring-loaded terminals or the KNX plug terminal. Configuration is performed via ETS 5 software, enabling individual setup of communication objects, group addresses, and logic functions. The logic functions include 2 AND and 2 OR gates, each with 4 inputs, consisting of 8 logic inputs in the form of communication objects. The gate outputs can be optionally configured as 1 bit or 2 x 8 bits.
Operational Advantages
The Elsner KNX eTR M2 offers intuitive operation through touch-sensitive surfaces and visual feedback via integrated LEDs. The combination of switch function and temperature sensor enables flexible use in heating and lighting control systems. The ability to integrate external temperature values and calculate mixed values increases the accuracy of room temperature detection. Configuration via ETS 5 allows flexible adaptation to different application scenarios. The robust construction from real glass and plastic, along with compliance with standards for overvoltage category III and pollution degree 2, ensures reliable operation in typical indoor environments. The shallow mounting depth of 12.5 mm allows for flat installation in standard flush-mounted boxes.