Elsner 70820, EAN: 4051996708209

Elsner 70820 KNX sensor CO2 temp humidity white

Elsner 70820 KNX sensor CO2 temp humidity white

Lieske Part No. 701109
Mfg Part No 70820
EAN-Code 4051996708209
Manufacturer Elsner
Here only 439,00 EUR
522,41 EUR incl. VAT

Further information for Elsner 70820 KNX sensor CO2 temp humidity white

General
HousingReal glass, plastic
Display visible diagonal2.3" (59 mm)
Display resolution [pixels]320 × 240
Colours (similar)RAL 9010 (white), RAL 9005 (black)
Degree of protectionIP20
Dimensions (W × H × D) mounting ring (W × H) depth55 mm × 55 mm × 35 mm, 71 mm × 71 mm, 7 mm
Weight total≈ 90 g
Ambient temperature0…+45°C / -5…+45°C / -5…+45°C
Ambient air humidity (rH) (non-condensing)5...95 %
Storage temperature25...+70°C
Over voltage categoryIII
Pollution degree2
Inputs
Number4
Contact voltage3.3 V
Contact current0.33 mA
Temperature sensor T-NTC (No. 30516) measurement range at input40...+80°C
Maximum cable length T-NTC / digital inputs3 m / 10 m
KNX bus
MediumTP1-256
Configuration modeS-Mode
Maximum group addresses2000
Maximum assignments2000
Communication objects471 / 433 / 379
Nominal voltage30V DC SELV
Electricity consumption≤ 18mA
Connection KNX plug-in terminal conductor diameter0.6…0.8 mm s
Connection KNX plug-in terminal stripping length5 mm
Time until data reception after bus voltage recovery≈ 5 s
Sensors
CO2 measurement range400...5000 ppm
Humidity measurement range5...95 %
Temperature measurement range5…+60°C
The Elsner Cala Touch KNX AQS/TH 3.x (type 70820) is a room controller with integrated CO2, temperature, and humidity sensor, specifically designed for integration into KNX heating, ventilation, and lighting systems. The device features a colour touch display with a visible diagonal of 2.3 inches (59 mm) and a resolution of 320 × 240 pixels, supporting various display and control pages. It serves as a central control and display element indoors, enabling monitoring and control of climate and lighting parameters. The housing is made of real glass and plastic, available in pure white (RAL 9010), and complies with protection class IP20. The dimensions of the mounting ring are 55 mm × 55 mm × 35 mm, the installation depth is 7 mm, and the total weight is approximately 90 g. The device is designed for an ambient temperature of 0 to +45 °C and a humidity of 5 to 95 % (non-condensing). The storage temperature ranges between 25 and +70 °C. The overvoltage category is III, and the pollution degree is 2.

Applications

The room controller is suitable for decentralised control of climate and lighting systems in residential and office buildings. It measures CO2 concentration (400 to 5000 ppm), relative humidity (5 to 95 %), and temperature (5 to +60 °C) in the room. These values can be used to control ventilation and heating systems to ensure a comfortable indoor climate. The integrated weekly time switch with eight time slots enables time-based control of lighting, heating, and ventilation. The device can also serve as a secondary station for operating another controller.

Functions and Equipment in Detail

The touch display shows various pages, including current measurement value display, a bus data display with four universal display positions, temperature control with mode switching (heating/cooling), and control elements for lighting (switching, dimming, RGB, colour temperature, Human Centric Lighting), shading, window drive, scenes, and bus information. Operation is performed via touch elements, sliders, and buttons. The integrated weekly time switch supports automated control throughout the day and week. Additionally, functions such as screen saver (clock, alternating clock/indoor temperature/outdoor temperature, off) and key tone can be turned on or off.

Technology Explained Simply

The controller operates in the KNX network via the TP1-256 medium in S-Mode. The nominal voltage is 30 V DC SELV, and the current consumption is up to 18 mA. The communication objects include up to 471/433/379, with maximum group addresses and assignments each amounting to 2000. The KNX terminal block supports wire diameters of 0.6 to 0.8 mm s with a stripping length of 5 mm. After the bus voltage is restored, it takes approximately 5 seconds to receive data. The integrated PI controllers regulate heating/cooling (based on temperature) and ventilation (based on humidity or CO2). Control is performed according to separate setpoints or base set temperature. The device is suitable for fan-coil control on fan convectors. Measurement values can be mixed with external values, with the proportion being adjustable in percentage. The calculation of the dew point and notification whether values lie within the comfort zone (DIN 1946) are also integrated.

Compatibility and Accessories

The device is designed for use with the KNX bus system and can communicate with other KNX components. The integrated logic functions include 8 AND and 8 OR logic gates, each with 4 inputs. Inputs can be switching events or 16 logic inputs in the form of communication objects. The gate outputs can be configured as either 1 bit or 2 × 8 bits. Additionally, 8 multifunction modules are integrated, which can calculate input data, check conditions, or convert data point types. The 4 inputs support binary contacts or the temperature sensor T-NTC (no. 30516) with a measurement range of 40 to +80 °C. The maximum cable length is 3 m for the T-NTC sensor and 10 m for digital inputs.

Mounting and Installation

The controller is installed into a suitable switch series, with the frame adapted to the switch series used in the building. Installation is carried out in a standard installation switch box. The terminal block for the KNX bus is designed for wire diameters of 0.6 to 0.8 mm s. The stripping length is 5 mm. Installation is performed according to the specifications of the KNX system and electrical standards.

Operational Advantages

The room controller enables central, user-friendly control of climate and lighting systems. The integrated sensors provide precise measurement values used for automatic control of heating, ventilation, and lighting. The weekly time switch and logic functions allow flexible, time- and condition-dependent control. Adaptation to various switch series ensures seamless integration into interior fittings. Threshold values can be set via parameters or communication objects, enabling flexible configuration. The integrated PI controllers ensure precise control of ventilation and heating/cooling. Batteries are not included in the delivery scope.