| General |
| Housing | real glass, plastic, metal |
| Display visible diagonal | 2.3" (59 mm) |
| Display resolution [pixels] | 320 × 240 |
| Housing colour (similar) | RAL 9010 (white), RAL 9005 (black) |
| Degree of protection | IP20 |
| Dimensions (W × H) | 60 mm × 60 mm |
| Installation depth | ≥ 10mm |
| Weight total | ≈ 70 g |
| Ambient temperature | Cala Touch KNX AQS/TH CH: 0…+45°C, Cala Touch KNX TH CH: -5…+45°C, Cala Touch KNX T CH: -5…+45°C |
| Ambient air humidity (rH) (non-condensing) | 5...95 % |
| Storage temperature | 25...+70°C |
| Over voltage category | III |
| Pollution degree | 2 |
| Inputs |
| Number | 4 |
| Contact voltage | 3.3 V |
| Contact current | 0.33 mA |
| Temperature sensor T-NTC (No. 30516) measurement range at input | 40...+80°C |
| Maximum cable length T-NTC / digital inputs | 3 m / 10 m |
| KNX bus |
| Medium | TP1-256 |
| Configuration mode | S-Mode |
| Maximum group addresses | 2000 |
| Maximum assignments | 2000 |
| Communication objects | Cala Touch KNX AQS/TH CH: 471, Cala Touch KNX TH CH: 433, Cala Touch KNX T CH: 379 |
| Nominal voltage | 30V DC SELV |
| Electricity consumption | ≤ 25 mA |
| Connection KNX plug-in terminal conductor diameter | Ø 0.8 mm s |
| Connection KNX plug-in terminal stripping length | 5 mm |
| Time until data reception after bus voltage recovery | ≈ 5s |
| Sensors |
| CO2 measurement range | 400...5000 ppm |
| Humidity measurement range | 0...100 % |
| Temperature measurement range | 5…+60°C |
The Elsner Cala Touch KNX T 3.x CH is a room controller with an integrated temperature sensor, specifically designed for integration into KNX heating and building automation systems. The device features a colour-active touch display with a visible diagonal of 2.3 inches (59 mm) and a resolution of 320 × 240 pixels, used for displaying measurement values, control elements, and menu options. The housing is made of real glass, plastic, and metal and is finished in RAL 9010 (white), allowing it to visually integrate into existing switch rows. The protection rating IP20 safeguards against finger contact and ingress of solid foreign objects larger than 12.5 mm, with the device designed for indoor use. Dimensions are 60 mm × 60 mm (width × height), the mounting depth is at least 10 mm, and the total weight is approximately 70 g. The operating ambient temperature ranges from -5 °C to +45 °C, and the humidity may reach up to 95 % (non-condensing).
Applications
The room controller is used in intelligent building systems to measure and regulate room temperature. It is suitable for residential and office buildings where central control of heating, cooling, lighting, and shading via the KNX protocol is required. The integrated temperature sensor enables the detection of indoor temperature, with a measurement range from 5 °C to +60 °C. Additionally, the controller can receive external temperature values via the KNX bus system and combine them with the internal measurement value to calculate a mixed value, thereby determining a representative room temperature value. This value can be used to control switching outputs, for example, to activate heating or cooling units.
Functions and Equipment in Detail
The device includes an integrated PI controller used for temperature-based control of heating and cooling processes. The control can be single- or two-stage, with separate setpoint values or a base setpoint configurable. A special control function is provided for fan coil units. Operation is performed via the touch display, which offers various display and control pages, including a page for displaying current measurement values, a menu page for device settings, and pages for temperature control, lighting control (switching, dimming, RGB control, colour temperature adjustment), shading, and window drives. Lighting control also includes HCL control (Human Centric Lighting), which adjusts the light colour temperature over defined time periods. A weekly time switch with up to 8 time periods enables time-based control of functions. Additionally, 4 scenes are available with call-up, storage, and status indication.
Technology Explained Simply
The controller operates in S-Mode (Standard Mode) of the KNX bus system and uses the TP1-256 medium. The nominal voltage is 30 V DC SELV, with a maximum current consumption of 25 mA. Communication takes place via a KNX plug terminal designed for conductors with a diameter of Ø 0.8 mm and a stripping length of 5 mm. The maximum number of group addresses and assignments is 2000 each. Communication objects depend on the model: for the Cala Touch KNX T CH, the number is 379. The time until data reception resumes after a bus voltage recovery is approximately 5 seconds. Configuration is performed via the KNX software ETS. The integrated logic allows linking of states using AND and OR gates (each 8 with 4 inputs), where inputs can be either switching events or 16 logic inputs in the form of communication objects. The gate outputs can be configured as either 1 bit or 2 × 8 bits. Additionally, 8 multifunction modules (calculators) are available, which can modify input data through calculations, condition checks, or data point type conversions. Four setpoint comparators enable output of minimum, maximum, or average values from up to five received values. A summer compensation function for cooling adjusts the setpoint temperature according to the outdoor temperature, with minimum and maximum setpoints definable.
Compatibility and Accessories
The controller is designed for use with the KNX standard and can communicate with other KNX devices. The connection cable for the connection is included in the delivery. Installation is performed using a supplied mounting bracket with screws. The plug terminal for the KNX bus is also included in the delivery. The inputs support binary contacts as well as the temperature sensor T-NTC (article number 30516), which has a measurement range from 40 °C to +80 °C. The maximum cable length for the T-NTC sensor is 3 m, and for digital inputs, it is 10 m. The sensors measure CO2 in the range of 400 to 5000 ppm, humidity from 0 to 100 %, and temperature from 5 to +60 °C.
Installation and Mounting
Installation is carried out in a standard installation cavity with a mounting depth of at least 10 mm. Mounting is done using the supplied mounting bracket, which is secured with screws. The KNX plug terminal is connected to the bus cable, ensuring a stripping length of 5 mm and a conductor diameter of Ø 0.8 mm. Configuration is performed via the KNX software ETS, where device settings, logic functions, scenes, and time schedules are parameterised. The connection cable for the connection is included in the delivery.
Operational Advantages
The controller offers comprehensive functionality for room control, including temperature measurement, mixed value calculation, PI control, lighting and shading control, and scene functions. The touch operation enables intuitive use, while the integrated logic and communication objects allow flexible adaptation to individual requirements. Support for HCL control and weekly time switch enhances comfort functions. Configuration via ETS ensures professional integration into existing KNX systems. The overvoltage category III and pollution degree 2 ensure reliability in typical indoor environments. Storage is at temperatures from 25 °C to +70 °C.
Delivery Contents
The device is delivered with housing and display, mounting bracket with screws, KNX plug terminal, and connection cable for the connection. The connection cable is intended for connecting the device. The mounting bracket enables fixation in a standard installation cavity. The plug terminal is designed for the KNX bus cable.