Dold 0069879, EAN: 4030641698799

Dold 0069879 RN5893.12/010/61 insulation monitor 1k-500k

Dold 0069879 RN5893.12/010/61 insulation monitor 1k-500k

Lieske Part No. 1001698
Mfg Part No 0069879
EAN-Code 4030641698799
Manufacturer Dold
Here only 692,36 EUR
823,91 EUR incl. VAT

Further information for Dold 0069879 RN5893.12/010/61 insulation monitor 1k-500k

Technical data
ApprovalsUL-Recognized
Bus interfaceModbus RTU
ClassificationFor DC charging stations
Enclosure designDistribution board
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 230 V, AC 0 - 690 (Coupling device) V, DC 0 - 230 V, DC 0 - 1000 (Coupling device) V
Response value1 - 500 kΩ
Response value typeAdjustable
Width52,5 mm
TypeRN 5893
Earth fault indicatorYes
Variant
Alarm value1 - 500 kOhm
Auxiliary voltageAC/DC 100 - 240 V
Contact equipping2 x 1 changeover contact
Prewarning value1 - 500 kOhm
Approvals and MarkingsUL-rec. C/US
VariantFür Netzableitkapazitäten bis 30 µF
The insulation monitor RN5893.12/010/61 from Dold is a device for monitoring insulation in IT systems, particularly in ungrounded AC, DC, and mixed AC/DC networks. It is specifically designed for use in DC charging stations for electric vehicles operating according to IEC/EN 61851-23:2014/AC:2016-06. The device enables continuous monitoring of insulation resistance and detects both symmetrical and asymmetrical insulation faults. Selective earth fault detection via L+ and L- supports rapid fault localization in the network. The operating voltage for the auxiliary supply is in the range AC/DC 100–240 V, making the device suitable for various industrial and stationary applications.

Applications

The RN5893 is universally applicable in ungrounded networks with voltages up to AC 250 V or DC 300 V. When used with an external pre-stage device RP 5898, higher nominal voltages up to AC 690 V and DC 1000 V can also be monitored. Main application areas include DC charging stations, UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. Monitoring also occurs when the network is de-energized, ensuring continuous safety.

Functions and Equipment in Detail

The device features two independently adjustable trip thresholds, which can be used for pre-alarm and alarm functions. The adjustment range for both values is between 1 kΩ and 500 kΩ. Adjustment is performed via two rotary switches on the front of the device, enabling user-friendly parameterization. Additionally, device configuration can be done via a Modbus RTU interface, allowing reading and setting of measured values, statuses, and parameters. Display is via a multi-colored illuminated screen showing the current insulation resistance, device status, and other parameters. A manual self-test is available, with an optional automatic self-test. Alarm memory can be selected, and the measurement circuits L(+) and L(−) are monitored for wire break (can be disabled). The protective conductor connection PE1/PE2 is also monitored for wire break, but cannot be disabled.

Technology Explained Simply

The insulation monitor operates according to the insulation monitoring principle as per IEC/EN 61557-8. It measures the insulation resistance between the conductors and the protective conductor and reacts when the set thresholds are exceeded. The response time for the RN5893/010 variant is less than 10 seconds. Measurement also occurs during voltage fluctuations, with the network voltage being evaluated to ensure optimized measurement. The network capacitance for this variant is rated up to 30 µF, suitable for installations with higher capacitance. The galvanically isolated changeover contacts (2 x 1 changeover contact) allow flexible use for various alarm functions, such as pre-alarm, alarm, or device fault. The operating or rest current principle for the alarm relays is adjustable, facilitating integration into existing safety concepts.

Compatibility and Accessories

The device is designed for use with an external pre-stage device RP 5898, enabling monitoring of higher voltages up to AC 690 V and DC 1000 V. The Modbus RTU interface allows integration into higher-level control and monitoring systems. The tamper-proof transparent cover protects the device against unauthorized manipulation. The width is 52.5 mm, enabling installation in standard installation distributors.

Mounting and Installation

The insulation monitor is mounted in installation distributors. Mounting is done on a standard 35 mm rail profile. The connection terminals are designed for connecting to the network conductors and the protective conductor. The auxiliary supply is connected via designated terminals. Parameterization is done via the front switches or via the Modbus interface. The tamper-proof cover is installed after configuration to prevent manipulation.

Operational Advantages

The RN5893 provides preventive fire and system protection through early detection of insulation faults. Rapid fault localization via selective earth fault detection reduces downtime. Flexible parameterization and Modbus integration allow adaptation to specific requirements. Monitoring even when the network is de-energized increases safety. Galvanic isolation of contacts and the tamper-proof cover enhance reliability and device protection.

Approvals and Markings

The device carries the UL-Recognized C/US approval, enabling use in corresponding markets. Compliance with IEC/EN 61557-8 and IEC/EN 61851-23:2014/AC:2016-06 is guaranteed. The width of 52.5 mm corresponds to the standard for installation distributors. The auxiliary supply AC/DC 100–240 V allows flexible installation in various environments.

Enclosure Design and Mounting

The device is designed as an installation distributor and is mounted on a standard 35 mm rail profile. The front panel features two rotary switches and a multi-colored display. The tamper-proof transparent cover protects the control elements. The connection terminals are intended for connecting to the network conductors, protective conductor, and auxiliary supply. The Modbus RTU interface is galvanically isolated and enables communication with higher-level systems.

Functions for Fault Detection and Localization

Selective earth fault detection via L+ and L− enables rapid fault localization. Circuit monitoring for wire break (L+/L−) and protective conductor connection monitoring (PE1/PE2) increase reliability. Alarm memory and hysteresis function prevent false triggering. Adjustable trip thresholds and the operating or rest current principle for alarm relays allow adaptation to specific requirements.

Integration into Systems

The Modbus RTU interface allows integration into higher-level control and monitoring systems. All measured values, statuses, and parameters can be read and configured. Galvanic isolation of the interface increases safety. The tamper-proof cover protects the device against manipulation. The width of 52.5 mm enables installation in standard installation distributors.

Safety Functions

Monitoring even when the network is de-energized increases safety. Circuit monitoring for wire break (L+/L−) and protective conductor connection monitoring (PE1/PE2) prevent malfunctions. Alarm memory and hysteresis function prevent false triggering. The tamper-proof transparent cover protects the device against unauthorized manipulation.

Application in DC Charging Stations

In DC charging stations for electric vehicles, the RN5893 is particularly suitable as it meets the requirements of standard IEC/EN 61851-23:2014/AC:2016-06. Monitoring of insulation faults in ungrounded DC networks with voltages up to DC 1000 V (with pre-stage device) ensures the safety of the installation. Fast response time and selective fault localization reduce downtime. Modbus integration enables monitoring via a central system.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001698