Further information for Dold 0069311 still-run monitor UH=DC24V

Technical data
ClassificationSensorless, Stillstandsüberwachung
Enclosure designSwitch cabinet
Measuring range max.4 V, 400 mV
Output contacts1 NC contact, 2 NO contacts
Width22,5 mm
TypeUG 9146
Operate delayYes
Variant
Auxiliary voltageDC 24 V
Contact equipping2 NO contacts, 1 NC contact
Response value0,2 - 4 V
Terminal typeplug in screw terminal
Time range0,2 - 6 s
Approvals and MarkingsUL-listed C/US, UKCA
The Dold UG9146.22PS/61 is a sensorless standstill monitor used for monitoring electric motors for standstill. The device measures the induced voltage at two terminals of the stator winding of the decelerating motor. When the induction voltage drops towards zero, this is interpreted as motor standstill and the output relay switches on. The function is based on the remanent voltage generated during motor deceleration due to residual magnetization. The standstill monitor is suitable for 3-phase and 1-phase motors and operates independently of rotation direction.

Applications

The UG9146 is used in industrial applications where precise detection of standstill is required, for example for speed-dependent switching in production processes, to activate holding brakes, or to signal to higher-level control systems. It is also suitable for use with frequency converters, as it measures the induced voltage directly at the motor and does not rely on external sensors.

Functions and Equipment in Detail

The device features an adjustable voltage threshold (0.2 to 4 V), which defines the value below which standstill is detected. Additionally, the standstill time (0.2 to 6 seconds) is adjustable to determine the delay between falling below the voltage threshold and switching of the output contacts. This adjustability allows adaptation to various motor types and applications. The output contacts are forced-guided and consist of two closers (for AC 250 V) and one opener (for DC 24 V). The terminal type is a plug-in screw terminal, ensuring a secure and quick connection.

Technology Explained Simply

The operation is based on measuring the induced voltage (EMF) at the motor. During motor deceleration, a voltage is generated by residual magnetization, which is proportional to the rotational speed. If this voltage falls below the set threshold, standstill is detected. The response delay ensures that short-term voltage fluctuations are not interpreted as standstill. The LED indicators signal the operating status: the green-red LED UH" lights green when supply voltage is present, the yellow-green LED "OUT" lights yellow when the EMF is above the threshold, blinks green during the standstill time, and lights green continuously when the output contacts are enabled. The red LED "ERR blinks in case of internal errors.

Compatibility and Accessories

The standstill monitor is designed for use with 3-phase and 1-phase electric motors that generate a remanent voltage during deceleration. It is compatible with frequency converters. The device connections are implemented as plug-in terminal blocks with screw terminals (type UG 9146 PS). The auxiliary voltage is DC 24 V. The width is 22.5 mm, enabling installation in standard enclosures. The certifications include UL-listed C/US and UKCA.

Mounting and Installation

Mounting is done in an enclosure. Terminals L1-L2 are connected to the motor terminals, while the auxiliary voltage is connected to A1-A2. The output contacts (13-14, 23-24, 31-32) are integrated into the control or safety circuit. The settings for voltage threshold and standstill time are adjusted using the designated adjustment options on the device. The LED indicators support commissioning and troubleshooting.

Advantages in Operation

The sensorless operation enables simple retrofitting without additional sensors. The fast response time and rotation-direction-independent detection increase reliability. The wire break detection in the measurement circuit (L1/L2) ensures that if a connection is defective, the output relay is deactivated, enhancing safety. The forced-guided contacts ensure secure signal transmission. Compliance with standard DIN/EN 60255-1 ensures electrical safety and reliability of the device.