Further information for Dold 0069310 Standstill Monitor DC24V
Technical data
Classification
Sensorless, Stillstandsüberwachung
Enclosure design
Switch cabinet
Measuring range max.
4 V, 400 mV
Output contacts
1 NC contact, 2 NO contacts
Width
22,5 mm
Type
UG 9146
Operate delay
Variant
Auxiliary voltage
DC 24 V
Contact equipping
2 NO contacts, 1 NC contact
Response value
20 - 400 mV
Terminal type
plug in screw terminal
Time range
0,2 - 6 s
Approvals and Markings
UL-listed C/US, UKCA
The Dold UG9146.22PS/61 is a sensorless standstill monitor used for monitoring electric motors for standstill. The device measures the induced voltage at two terminals of the stator winding of the decelerating motor. When the induction voltage drops towards zero, this is interpreted as motor standstill and the output relay activates. The function is based on the residual magnetization (remanence) of the motor, which generates a voltage during braking that is proportional to the rotational speed. The standstill monitor is suitable for 3- and 1-phase motors and operates independently of rotation direction. Applications include production environments for speed-dependent switching, activation of holding brakes, or signaling to higher-level control systems.
Applications
The UG9146 is used in industrial plants where precise detection of electric motor standstill is required. It is particularly suitable for installations operated with frequency converters, as it operates reliably even at variable speeds. The sensorless technology enables simple retrofitting without additional sensors or initiators. Applications range from process control to safety monitoring in machine building and manufacturing technology.
Functions and Equipment in Detail
The device features an adjustable trigger level for the voltage threshold (20 to 400 mV), which can be adapted to the specific characteristics of the monitored motor. Additionally, the standstill time is adjustable (0.2 to 6 seconds) to match the device's response time to application requirements. The output contacts are fail-safe and consist of two normally closed contacts (for AC 250 V) and one normally open contact (for DC 24 V). The LED indicators signal the operating status: green light for supply voltage, yellow for induced voltage above threshold, green flashing during standstill time, and steady green light when outputs are enabled. A red LED indicates internal faults.
Technology Explained Simply
The standstill monitor detects standstill by measuring the induced voltage generated by remanence as the motor coasts to a stop. This voltage decreases with decreasing rotational speed and reaches zero at standstill. The device detects this state and activates the output relays after the set standstill time has elapsed. The response delay ensures that short-term voltage fluctuations are not misinterpreted as standstill. Wire break detection in the measurement circuit (L1/L2) prevents false alarms by deactivating the output relay in case of interrupted measurement lines, which corresponds to the state of a running motor.
Compatibility and Accessories
The UG9146 is suitable for use with frequency converters and complies with the standard DIN/EN 60255-1. The auxiliary voltage is DC 24 V. The device connections consist of pluggable screw terminals (variant PS), enabling flexible installation in enclosures. The width is 22.5 mm, allowing compact placement in standard control panels. Certifications include UL-listed C/US and UKCA.
Mounting and Installation
Mounting is performed in enclosures. The auxiliary voltage is connected to terminals A1-A2, and the measurement lines to L1-L2. The output contacts (13-14, 23-24, 31-32) are connected to the control or safety circuit as required. The voltage threshold and standstill time settings are adjusted using the designated adjustment options on the device. The LED indicators support commissioning and maintenance by providing visual feedback on the operating status.
Advantages in Operation
The sensorless technology reduces the number of required components and lowers maintenance effort. The fast response time and adjustable parameters allow precise adaptation to different motors and applications. Wire break detection increases reliability by preventing false alarms caused by interrupted measurement lines. The fail-safe contacts ensure safety in case of failure, as they remain in the safe position even if the relay mechanically fails. Compatibility with frequency converters expands the application range in modern drive systems.