Dold 0068515, EAN: 4030641685157

Dold 0068515 UG9400.12PM 3AC24-690V AC12A multifunction measuring relay

Dold 0068515 UG9400.12PM 3AC24-690V AC12A multifunction measuring relay

Lieske Part No. 1001902
Mfg Part No 0068515
EAN-Code 4030641685157
Manufacturer Dold
Here only 422,67 EUR
502,98 EUR incl. VAT

Further information for Dold 0068515 UG9400.12PM 3AC24-690V AC12A multifunction measuring relay

Technical data
1- / 3-phase1, 3
Bus interfaceModbus RTU
Enclosure designSwitch cabinet
Measuring range max.690 V
Standard measuring range3 AC 24 - 690 V
Width22,5 mm
TypeUG 9400
Operate delayYes
Variant
Auxiliary voltageAC 60 - 400 V
Contact equipping2 x 1 changeover contact
Measuring currentAC 12 A
Measuring voltage3AC 24 - 690 V
Terminal typeplug in mixed terminals
VariantModbus RTU
The Dold UG9400.12PM is a multifunctional measuring relay of the VARIMETER PRO series, designed for monitoring electrical parameters in industrial installations. It enables simultaneous measurement and monitoring of up to nine different parameters, including voltage, current, frequency, phase angle cos phi, active, reactive and apparent power, as well as phase sequence and voltage asymmetry. The device is designed for use in single-phase and three-phase networks and is particularly suitable for applications requiring precise and reliable electrical monitoring, such as motor or transformer protection. Parameterization, monitoring and diagnostics are performed via a Modbus RTU interface, which is galvanically isolated, ensuring secure communication in industrial environments.

Applications
This measuring relay is used in industrial enclosures and is designed for use in complex and extensive installations. It enables early detection of irregularities in the power network, increasing plant availability and productivity. Typical application scenarios include motor protection against phase faults, transformer protection against unbalanced loading, and frequency monitoring on frequency converters. The ability to operate in both single-phase and three-phase networks significantly expands its application range.

Functions and Equipment in Detail
The device features 2 x 1 changeover contacts as contact configuration, used for signal output when threshold values are reached. The relay function can be parameterized for either operating or resting current, enabling flexible use. Monitoring is performed via minimum, maximum, or window monitoring, with hysteresis adjustable between 0.2 and 50 % of the pickup value. A fault memory documents occurring faults, enabling subsequent diagnostics. The start-up bypass time prevents changes at the input shortly after auxiliary voltage is applied from affecting the relay outputs.

Technology Explained Simply
Measurement is performed in the range 3AC 24 – 690 V for voltage and AC 12 A for current. The auxiliary voltage is supplied in the range AC 60 – 400 V, enabling the device to operate in various industrial voltage networks. The mounting width of 22.5 mm allows compact installation in standard enclosures. The pluggable mixed terminals simplify installation and maintenance. The Modbus RTU interface enables integration into higher-level control and monitoring systems. LED indicators signal the operating status: green LED ON" indicates that the supply voltage is present, red LED "ERR" flashes in case of faults, yellow LED "BUS" during Modbus communication, and green LEDs "REL2,5 cm ( 1 inch ) and "REL2 illuminate when relay outputs are activated.

Compatibility and Accessories
The device is designed for use in industrial environments and complies with the standard IEC/EN 60255-1. It is intended for use in enclosures and can be integrated into existing installations. The Modbus RTU interface enables communication with higher-level controls, allowing central monitoring and diagnostics. Parameterization is performed via the Modbus interface, enabling flexible adaptation to specific requirements.

Mounting and Installation
Mounting is performed in an enclosure, with the mounting width of 22.5 mm enabling compact placement. The pluggable mixed terminals simplify wiring. The auxiliary voltage is connected to terminals A1/A2, the measured voltage to L1/i, L2, L3, and the current measurement path to L1/i, k. The relay outputs are connected to terminals 11/12/14 and 21/22/24. The Modbus interface is connected via terminals A and B. The baud rate is adjustable via a potentiometer, with response time under 50 ms depending on the baud rate.

Operational Advantages
The measuring relay reduces wiring effort and lowers investment, operating and maintenance costs. Simultaneous monitoring of multiple parameters enables differentiated fault reporting and improves plant availability. Simple parameterization and diagnostics via Modbus RTU simplify maintenance and operation. The compact design and flexible adaptability make the device a cost-effective and space-saving solution for industrial monitoring tasks.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001902
qrcode für Dold 0068515 UG9400.12PM 3AC24-690V AC12A multifunction measuring relay