| Technical data |
| 1- / 2-channel | 2 |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | UG 6946 |
| Variant |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 NO contacts, 1 NC contact (internal NC contacts switched in series) |
| Response value | 20 - 400 mV |
| Terminal type | plug in screw terminal |
| Time range | 0,2 - 6 s |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA |
| Variant | With muting |
The
standstill monitor UG 6946.02PS/001/61 from Dold is a
sensorless safety device for direction-independent monitoring of standstill in 1- and 3-phase electric motors. The device detects standstill by measuring the induced voltage at the decelerating motor; once this voltage drops below 20 mV, the motor standstill is recognized and the output relay is activated. This eliminates the need for external sensors such as encoders or proximity switches. The
auxiliary voltage is DC 24 V, and the
trigger voltage is in the range of 20 to 400 mV. The
standstill time is adjustable between 0.2 and 6 seconds, allowing the device to be flexibly adapted to various applications.
Applications
The standstill monitor UG 6946 is designed for use in industrial safety applications, particularly in machine and plant engineering, where safe detection of motor standstill is required. It is suitable for operation with frequency converters and can be used in retrofit and upgrade projects, as it does not require additional sensors. The width of 22.5 mm allows for compact mounting in an enclosure, even in limited space.
Functions and equipment in detail
The device features
fail-safe safety output contacts, consisting of two normally closed contacts (for AC 250 V) and one normally open contact (for DC 24 V), with the internal normally open contacts connected in series. The contacts are accessible via
pluggable screw terminals, enabling flexible and secure wiring. A
wire break detection in the measurement circuit provides additional safety by detecting a defective connection. The
LED indicators signal operation, motor standstill, and wire break, allowing the operating status to be visually monitored.
Technology explained simply
The standstill monitor measures the induced voltage at the motor, which is generated during rotation. When the motor stops, this voltage drops to zero. The device detects this state and switches the safety outputs accordingly. The
adjustable trigger voltage and
standstill time allow adaptation to different motors and drive conditions. The
sealable transparent cover protects the rotary switches from unintended adjustment, increasing operational safety.
Compatibility and accessories
The device is compatible with the
safety mounting SAFEMASTER STS, facilitating integration into existing safety concepts. The certifications
UL-listed C/US, TÜV and UKCA confirm compliance with international safety standards. The
classification as sensorless and the
certification up to PL e and Category 4 according to EN ISO 13849-1 as well as
SIL 3 according to IEC/EN 62061 make the device suitable for high-safety applications.
Mounting and installation
Mounting is carried out in an enclosure, with the width of 22.5 mm enabling compact placement. Connections are made via pluggable screw terminals, ensuring a secure and reliable connection. Commissioning requires setting the trigger voltage and standstill time, with the manufacturer’s operating instructions to be observed.
Advantages in operation
The
sensorless operation reduces the number of required components and lowers maintenance costs. The
fast response time and
direction-independent detection increase reliability. The
possibility to bypass standstill monitoring (muting) allows temporary bypass operations, e.g. during maintenance work. The
LED indicators support fault diagnosis and operational safety monitoring.
Certifications and safety standards
The device complies with the requirements of
EN ISO 13849-1 (Category 4, PL e) and
IEC/EN 62061 (SIL 3). It is suitable for use in safety-critical applications, particularly in automation technology and machine engineering. The certifications
UL-listed C/US, TÜV and UKCA confirm compliance with international safety standards.
Use in safety-critical systems
The standstill monitor UG 6946 is designed for use in safety-critical systems, where detection of motor standstill is a prerequisite for safe operation. The
sensorless operation and
high safety certifications make it a reliable component in industrial safety concepts.
Application-specific features
The
adjustable trigger voltage (20–400 mV) and
standstill time (0.2–6 s) allow adaptation to different motors and operating conditions. The
wire break detection in the measurement circuit increases safety by detecting a defective connection. The
LED indicators signal operation, motor standstill, and wire break, allowing the device status to be visually monitored.