Further information for Dold 0068389 UG9256.11/301/61 3AC200-480V 0-1S motor starter soft start 9A
Technical data
1- / 3-phase
3
Approvals
UL
Auxiliary voltage
DC 24 V
Load current up to
9 A
Load voltage up to
3AC 200 - 480 V
On/Off Input Control
DC
Width
22,5 mm
Type
UG 9256
Signalling output
Temperature monitoring
Variant
Contact equipping
1 changeover contact
Nominal current
9 A
Nominal voltage
3AC 200 - 480 V
Ramp time
0 - 1 s
Approvals and Markings
UL-listed C/US, UKCA
Variant
With softstart. With ramp off at time potentiometer ton/off 0 ... 0,1 = without ramp. With mains isolating relay, on when no failure. Motor protection
The intelligent motor starter UG 9256 of the MINISTART series by Dold is a compact device for controlling and protecting 3-phase asynchronous motors. It enables soft start, direction change, and protection against overload and blocking. The device is designed for a rated voltage of 3AC 200–480 V and can safely switch load currents up to 9 A. The width of 22.5 mm allows space-saving installation in enclosures. Control is via digital inputs with an auxiliary voltage of DC 24 V. The contact configuration includes a changeover contact, used for controlling motor functions.
Applications
The motor starter is designed for applications requiring soft start and safe operational monitoring. These include, for example, door and gate drives, bridge and lifting drives, and conveyor systems with blocking monitoring. It is also suitable for process controls with drives where blocking monitoring is required. The devices are specified according to IEC/EN 60947-4-2 and can control motors with powers of 30 W to 150 W, 90 W to 750 W, or 550 W to 4 kW at AC 400 V. The functions are designed for use in industrial environments where high availability and reliability are required.
Functions and equipment in detail
The device offers up to six functions in one module: soft start, soft stop, direction change (left and right rotation), current monitoring, and motor protection. Direction change is achieved via relay switching, where relays are switched without current to ensure long service life. Soft start is implemented using thyristors, with two motor phases driven via phase control to enable a smooth increase in current and torque. The ramp time is adjustable in the range of 0 to 1 second. Current monitoring detects overcurrent if the set value is exceeded for more than 2 seconds. Temperature monitoring of the semiconductors ensures high device availability. An alarm output signals operational readiness when no fault is present.
Technology explained simply
The UG 9256 combines the advantages of robust relay technology with wear-free semiconductor technology. The hybrid relay technology enables reliable switching of motor phases, with relays switched without current to minimize wear. Control is via potentiometers on absolute scales, allowing settings for start torque, stop torque, soft start and soft stop time, as well as overcurrent limit or motor rated current. Indication is via four LEDs, visually signaling the operating status. Galvanic isolation between control and main current circuit ensures safe operation. The relay contact gaps are at least 0.5 mm, ensuring safe separation.
Compatibility and accessories
The device is designed for use with 3-phase asynchronous motors. Control is via galvanically isolated 24 V inputs for right and left rotation. A reset button is integrated on the device front, and there is the option to connect an external reset button. The alarm outputs can be used for operational readiness. An optional alarm output can be added upon customer request. The devices are UL-listed C/US and UKCA-certified, enabling use in the respective markets.
Mounting and installation
Mounting is in standard control panels with a width of 22.5 mm. The connection terminals are designed for connecting motor phases, control, and auxiliary voltage. Commissioning is done by adjusting the potentiometers on the absolute scales, enabling simple and time-saving configuration. The devices are designed for use in industrial environments and require no special mounting tools.
Advantages in operation
The motor starter offers high operational availability through temperature monitoring of semiconductors and high voltage resistance up to 1500 V. Currentless relay switching extends contact life. The integrated blocking protection protects the motor against overload. The space-saving design reduces required enclosure space by up to 80 %. User-friendliness is supported by visual indication via LEDs and simple adjustment via potentiometers. Galvanic isolation between control and main current circuit increases operational safety.
Approvals and markings
The device is UL-listed C/US and UKCA-certified. Approvals according to IEC/EN 60947-4-2 ensure compliance with international standards for electrical switching devices. Marking is in accordance with manufacturer approval requirements.
Functions at a glance
The devices offer soft start, soft stop, direction change, current monitoring, motor protection, and blocking protection. Settings are made via potentiometers on absolute scales. Indication is via four LEDs. Relay switching is currentless. Galvanic isolation between control and main current circuit is ensured. Contact gaps are at least 0.5 mm. Temperature monitoring of semiconductors ensures high availability. Semiconductor voltage resistance is up to 1500 V. Width is 22.5 mm. Auxiliary voltage is DC 24 V. Rated voltage is 3AC 200–480 V. Rated current is 9 A. Ramp time is adjustable from 0 to 1 second. Load voltage is up to 3AC 200–480 V. Load current is up to 9 A. Alarm outputs are present. Approvals include UL-listed C/US and UKCA.