| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Output contacts max. | 1 NC contact, 7 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 8 A |
| Width | 22,5 mm |
| Type | UG 6929 |
| Variant |
| Contact equipping | 5 NO contacts, 1 NC contact for feedback circuit |
| Nominal voltage | AC/DC 24 V |
| Terminal type | pluggable terminal blocks with cage clamp terminals |
| Approvals and Markings | UL-listed C/US, TÜV |
| Variant | For 2-channel connections |
The Dold expansion module UG6929.60PC/100/61 AC/DC24V is a safety relay module for use in industrial control systems, particularly for safe contact multiplication and amplification of safety modules. It serves to extend safety circuits controlled by a primary safety device and enables actuation with safety-oriented semiconductor outputs such as BWS or emergency stop switches. The module is designed for 1- or 2-channel wiring and features forced-guided contacts that ensure reliable and safe signal transmission.
Safety functions and approvals
This device meets the requirements of safety standards EN ISO 13849-1 with Performance Level (PL) e and Category 4, as well as IEC/EN 62061 with Safety Integrity Level (SIL) 3 and SIL Claimed Level (SIL CL) 3. These approvals make it suitable for use in safety-critical applications, for example in automation technology or in combustion systems where standard EN 50156-1 applies. The UL-listed C/US approval and TÜV certification confirm compliance with international safety standards.
Functions and equipment in detail
The module offers a maximum contact configuration of 7 NO contacts and 1 NC contact, with the NC contact specifically designated for the feedback circuit. This configuration enables safe monitoring of contact position and feedback of the operational status. The operational status indicator supports diagnosis and maintenance by visually signaling the current state of the module. The contacts are forced-guided, meaning they are mechanically designed so that opening one contact necessarily causes another to close — a critical factor for safety in critical applications.
Technology explained clearly
The rated voltage is AC/DC 24 V, enabling universal use in many industrial control systems. The maximum thermal current (Ith) is 8 A, defining the contact load capacity and ensuring stable operation even under higher loads. The module width of 22.5 mm corresponds to the standard for modular safety devices and allows compact installation in enclosures. The connection technology includes removable spring-cage terminals and removable screw terminals, enabling quick replacement and flexible wiring. Spring-cage terminals provide a reliable connection without additional tools, while screw terminals ensure a mechanically stable connection.
Compatibility and accessories
The module is designed for use with safety modules that offer safe output control. It can be operated with safety-oriented semiconductor outputs, facilitating integration into existing safety architectures. Use in 1- or 2-channel systems allows flexible adaptation to different safety requirements. The removable terminal blocks support quick device replacement, simplifying maintenance and repair.
Mounting and installation
Mounting is performed in standard control panels with a module width of 22.5 mm. The terminals are removable, allowing wiring without tools or with a simple screwdriver. The connection terminals are designed for secure and durable connections, with spring-cage terminals enabling quick installation. The operational status indicator is directly visible on the device and facilitates visual inspection during commissioning and maintenance.
Advantages in operation
The combination of forced-guided contacts, high safety certification, and flexible connection technology makes the module a reliable solution for safety-critical applications. The ability to operate with semiconductor outputs expands its application possibilities in modern control systems. The compact design and removable terminals reduce installation and maintenance times, increasing operational safety and efficiency. The certifications according to EN ISO 13849-1 and IEC/EN 62061 ensure compliance with international safety standards.