Dold 0067693, EAN: 4030641686932

Dold 0067693 RR5886/010 AC/DC85-230V test current generator

Dold 0067693 RR5886/010 AC/DC85-230V test current generator

Lieske Part No. 1002095
Mfg Part No 0067693
EAN-Code 4030641686932
Manufacturer Dold
Here only 1.108,54 EUR
1.319,16 EUR incl. VAT

Further information for Dold 0067693 RR5886/010 AC/DC85-230V test current generator

Technical data
Bus interfaceModbus RTU, RS-485
Nominal voltage IT systemDC, AC, 3AC 24 - 455 V
Operating modeMaster / Slave
Width105 mm
TypeRR 5886
Variant
Auxiliary voltageAC/DC 85 - 230 V
VariantFor rooms for medical purposes
The test current generator RR5886/010 AC/DC85-230V from Dold is a device for insulation fault detection in complex, isolated AC/DC networks (IT systems). It is used in conjunction with the insulation fault detection device RR 5887 to monitor and locate insulation faults. The external current transformer function enables independent operation of individual sensors, which are connected to the measurement channels of the RR 5887 and calibrated by it. Combining multiple insulation fault detection devices via an RS-485 bus connection increases the number of measurement channels and enables more precise fault localization in extensive networks. The Master/Slave operating mode supports synchronization of test current evaluation. The auxiliary voltage is AC/DC 85–230 V, enabling universal application in various operating voltage environments. The width of 105 mm corresponds to the standard for enclosures and allows compact mounting. The device variant is specifically designed for medical use areas, thus meeting safety and reliability requirements in sensitive environments.

Applications

The test current generator is intended for monitoring IT systems in industry, shipbuilding, plant engineering, and photovoltaic installations. It supports fault detection in networks with direct and alternating voltage (AC/DC) as well as in pure DC and AC systems within the voltage range of 24 to 455 V. Application in medical facilities requires high reliability and compliance with specific standards, which is ensured by conformity with DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1). Insulation coordination according to IEC 60664-1 ensures electrical safety and functionality under various operating conditions.

Functions and Equipment in Detail

The device supports output of positive and negative test current to monitor both DC networks and mixed systems with simultaneous alternating and direct current components. The test current output can be manually started via a button, with each button press alternately activating or deactivating the output. Alternatively, the test current release can be controlled via an external switching input (terminals Y1, Y2). Bridging these terminals deactivates the start/stop button. The status output of the insulation fault detection is provided via an external switching output (terminals G, H). Device indicators include a green LED ON" for operating voltage, a yellow LED "BUS for RS-485 bus activity, and yellow LEDs for the output of positive and negative test current pulses.

Technology Explained Simply

The RS-485 bus connection enables synchronization of test current evaluation and system expansion through multiple devices. The Modbus RTU interface is used for controlling insulation fault detection and reading measured fault currents. Galvanic isolation of the RS-485 bus connection terminals (SH, GND, Rb, B, A, Ra) protects the device from interference and voltage spikes. External control via an insulation monitor allows integration into existing monitoring systems. The automatic calibration function and clear design of adjustment elements simplify operation and reduce error susceptibility.

Compatibility and Accessories

The test current generator RR5886 is specifically designed for use with the insulation fault detection device RR 5887. The combination of both devices enables localization of insulation faults in complex IT systems. The RS-485 bus connection supports system expansion through multiple RR 5887 devices, thereby increasing the number of measurement channels. The Modbus RTU interface enables integration into fieldbus systems and remote control of test current output.

Mounting and Installation

Mounting is performed in standard enclosures with a width of 105 mm. Connections for auxiliary voltage (A1, A2), IT network voltage (L1, L2, L3, PE), and RS-485 bus (SH, GND, Rb, B, A, Ra) are clearly labeled. The switching inputs (Y1, Y2) and switching output (G, H) enable integration into existing control and monitoring systems. Terminal designations are detailed in the datasheet to ensure error-free installation.

Operational Advantages

Early detection and localization of insulation faults enable quick and targeted correction, increasing network operational safety and availability. The two alarm levels support timely recognition of a dangerous insulation condition. The universal auxiliary voltage and easy operation through automatic calibration functions and clear indicators reduce maintenance effort and increase monitoring efficiency. Application in medical use areas requires high reliability, which is ensured by the specific design of the variant.