The emergency stop module UF6925.03/61 DC8-36V from Dold is a safety-oriented switching component designed for use in industrial systems. It serves for the safe enabling and interruption of a safety circuit, particularly in combination with emergency stop pushbuttons and safety doors. The device is designed for use in safety-critical applications and meets the requirements of safety standards EN ISO 13849-1 and IEC/EN 62061. It features a 2-channel design with fail-safe output contacts, ensuring reliable signal transmission. The contact configuration includes 3 normally open contacts, suitable for controlling safety functions.
Applications
This module is intended for applications in industrial safety technology, particularly in machine and plant engineering. It can be used in systems specified according to EN 61511 or EN 50156-1 for burner systems. Its function as a safety door monitor enables integration into protective enclosures, which safely shut down machine operation upon opening. The application is in environments requiring high safety integrity, such as in manufacturing industry or in plants with moving parts.
Functions and Equipment in Detail
The device features an adjustable start function, which can be activated either manually via a single button or automatically. This flexibility allows adaptation to different operating procedures. The cross-connection detection in the control circuit is also adjustable and serves to detect short circuits, avoiding false alarms. Indication is provided via LED indicators for channel 1, channel 2, and power supply, visually signaling the operating status. Connections are made via front-mounted spring-loaded terminals, enabling quick and secure wiring.
Technology Explained Simply
The module operates with a rated voltage range of DC 8 to 36 V, making it suitable for a wide range of industrial power supplies. The maximum thermal current is 8 A, defining the contact load capacity. The width of 17.5 mm allows for compact mounting in standard control panels. The safety functions are designed for category 4 and performance level e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061, meeting the highest requirements for safety integrity. The fail-safe contacts ensure that the switching function is reliably executed even in the event of mechanical interference.
Compatibility and Accessories
The module is designed for use with emergency stop pushbuttons and safety doors. Combination with other safety components is possible, provided the system requirements for safety integrity and electrical parameters are met. The connection terminals are designed for standard cables. The certifications UL-listed C/US and TÜV confirm compliance with international safety standards.
Mounting and Installation
Mounting is carried out in standard control panels with a width of 17.5 mm. The front-mounted spring-loaded terminals allow for quick and secure connection of wires. Installation does not require special tools, as the terminals can be operated manually. Positioning within the enclosure should ensure that the LED indicators are clearly visible and connections are easily accessible.
Advantages in Operation
The module offers high safety integrity by complying with standards PL e / Cat. 4 and SIL 3. Adjustable functions such as start mode and cross-connection detection allow flexible adaptation to specific requirements. The compact design and front-mounted terminals reduce installation effort. The LED indicators facilitate diagnostics during operation, as the status of the channels and power supply is directly visible. Use in safety doors enables safe shutdown upon opening, enhancing personnel safety.