Dold 0067212, EAN: 4030641672126

Dold 0067212 residual current device type B 0-10s

Dold 0067212 residual current device type B 0-10s

Lieske Part No. 100086
Mfg Part No 0067212
EAN-Code 4030641672126
Manufacturer Dold
Here only 571,32 EUR
679,87 EUR incl. VAT

Further information for Dold 0067212 residual current device type B 0-10s

Technical data
Adjustable measuring ranges0,01 - 3 A
ApprovalsUL
ClassificationType B (AC, DC even and pulsating)
Enclosure designDistribution board
Type of voltageAC, DC
Width52,5 mm
TypeRN 5883
Broken conductor detectionYes
Clear keyYes
Operate delayYes
Relay contact / outputYes
Test keyYes
Variant
Auxiliary voltageAC/DC 80 - 230 V
Contact equipping1 changeover contact for prewarning, 1 changeover contact for alarm
Measuring range10 - 3000 mA
Time delay0 - 10 s
Approvals and MarkingsCCC
VariantFor current transformer ND5018/105, ND5018/140, ND5018/210. Without analogue output
The Dold residual current monitor RN5883.12/020 is a universal current-sensitive monitoring switch for earthed networks, used for early detection of insulation faults. The device operates according to Type B principle (for AC, DC smooth and pulsating) and detects residual currents in the range of 10 mA to 3 A. Measurement is performed via an external current transformer, with the RN5883.12/020 variant specifically designed for current transformers ND5018/105, ND5018/140, and ND5018/210. Unlike an RCD, the residual current monitor does not automatically switch off, but instead signals the fault via optical indicators, enabling targeted maintenance.

Applications

The RN5883.12/020 is designed for use in industrial and commercial installations, particularly in systems with mixed current types (AC and DC). It is suitable for monitoring machines, drives, lighting systems, and other electrical installations where early fault detection is critical to avoid failures and fire hazards. The application is in earthed networks, where insulation faults are detected at an early stage, before a critical condition occurs.

Functions and Equipment in Detail

The device features two relay contacts: one changeover contact for pre-alarm and one changeover contact for alarm. Indication is provided via an LED bar that visually displays the current residual current value, as well as separate LEDs for operational readiness, pre-alarm, and alarm. Integrated functions include wire break detection, test button, and reset button, enabling safe and controlled diagnosis and maintenance. The switching delay is adjustable from 0 to 10 seconds, allowing adaptation to specific requirements. The operating mode can be selected between idle current and working current principle.

Technology Explained Simply

The residual current monitor operates with external measurement via a current transformer that encloses the circuit to be monitored. The difference between incoming and outgoing current is detected and signaled if the set threshold is exceeded. The universal current-sensitive design (Type B) allows detection of faults under both AC and DC conditions, making it suitable for diverse applications in modern electrical systems. The operating voltage is in the range of AC/DC 80 to 230 V, enabling flexible integration into existing networks.

Compatibility and Accessories

The RN5883.12/020 is specifically designed for current transformers ND5018/105, ND5018/140, and ND5018/210. An optional analog output is available, however, the RN5883.12/020 variant is supplied without analog output. The devices are specified according to IEC/EN 62020 and VDE 0663, with UL and CCC approvals confirmed.

Mounting and Installation

The device is designed as an installation distributor with a width of 52.5 mm, enabling mounting in standard distribution boxes. Commissioning is performed via the designated connection terminals, with settings for measurement range, switching delay, and operating principle adjusted via rotary switches. The tamper-proof transparent cover provides adjustment protection to prevent unauthorized changes.

Advantages in Operation

By enabling early detection of insulation faults, the RN5883.12/020 allows targeted maintenance before plant downtime occurs. The visual indication via LED bar and status LEDs ensures rapid fault localization. The combination of pre-alarm and alarm with memory function supports documentation of disturbances. Universal applicability in AC/DC networks and flexible parameter adjustment increase system availability and reduce maintenance costs.