| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Forcibly guided output contacts max. | 2 NO contacts |
| Indicator contacts | 2 Semiconductor monitoring outputs |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 8 A |
| Width | 45 mm |
| Type | UH 6937 |
| Variant |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 NO contacts |
| Terminal type | pluggable terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
| Variant | Max. response value 1000 Hz |
The frequency monitor UH6937.02PS/100/61 DC24V from Dold is a safety-relevant monitoring switch for alternating voltages and rotation directions in industrial drive systems. It is designed for safe frequency monitoring of single-phase or three-phase alternating voltages, as well as for monitoring phase sequence or rotation direction in three-phase systems. The application includes monitoring the output frequency of frequency converters, the rotor frequency of slip ring motors, and drives in crane systems. The device is designed for safety applications up to PL e / Category 4 according to EN ISO 13849-1 and SIL 3 according to IEC/EN 62061, with rotation direction monitoring classified as PL d / Category 2 and SIL 2. Parameterization is performed via a front-mounted display, enabling menu-guided settings and supporting the display of set and actual values for frequency and rotation direction.
Applications
This frequency monitor is specifically designed for use in drive technology, particularly in inverter systems where precise frequency and rotation direction monitoring is required. It is suitable for frequency converters up to 1200 Hz, with the current variant having a maximum response value of 1000 Hz. The universal measurement inputs allow connection to AC voltages from 8 to 280 V for single-phase monitoring and from 16 to 690 V for single- and three-phase applications. The devices are suitable for use in safety-critical installations, such as in material handling, metalworking, or packaging technology, where error-free rotation direction and frequency stability are essential.
Functions and Features in Detail
The device features two forced-guided close contacts as output contacts, ensuring safe switching operations in safety functions. Galvanic isolation between the measurement input, auxiliary voltage, and output contacts ensures high electrical safety. Parameterization is performed via a front-mounted display, enabling comfortable, menu-guided settings. Adjustment options include variable hysteresis, a release delay from 0 to 100 seconds, a start-up bypass time from 0 to 100 seconds, and an alarm delay from 0 to 100 seconds. For rotation direction monitoring, a tolerance of 5 to 60000 periods is adjustable. Alarm memory or auto-reset can be configured. Additionally, integrated LED indicators and two semiconductor alarm outputs signal the operating status visually and electronically.
Technology Explained Simply
The operation is based on measuring the period duration of the input frequency, enabling fast response time. Input signals are captured via universal measurement inputs designed for a wide voltage range. The auxiliary voltage is DC 24 V, representing a standard supply in industrial control systems. Connection is made via removable terminal blocks with screw terminals, ensuring secure and quick connections. The width is 45 mm, allowing compact mounting in standard control panels. The devices are sensorless, meaning no additional sensors are required.
Compatibility and Accessories
The frequency monitor is designed for integration into existing drive solutions and can be directly mounted in control panels. The removable terminal blocks allow for quick device replacement. The devices are suitable for frequency converters up to 1200 Hz, with the current variant having a maximum response value of 1000 Hz. Certifications include UL-listed C/US, TÜV, UKCA, and CCC, enabling use in various markets. The devices are designed for frequency monitoring up to SIL 3 according to EN IEC 62061 and EN 61511, and for rotation direction monitoring up to SIL 2 according to the same standards.
Mounting and Installation
Mounting is performed in standard control panels with a width of 45 mm. The removable terminal blocks with screw terminals enable secure and quick connections. Parameterization is done via the front-mounted display, eliminating the need for additional control systems or PC software. The devices are designed for industrial environments and require no special mounting conditions.
Operational Advantages
The frequency monitor offers high safety through forced-guided output contacts and galvanic isolation. Menu-guided parameterization via the display enables simple and time-saving commissioning. Comprehensive diagnostic functions reduce downtime, as faults can be quickly identified. The universal measurement inputs and adjustable settings for hysteresis, delays, and tolerances allow flexible adaptation to different applications. Integrated LED indicators and semiconductor alarm outputs ensure clear signaling of the operating status.
Frequency monitor,
safe frequency monitoring,
rotation direction monitoring,
forced-guided output contacts,
PL e / Cat. 4,
SIL 3,
removable screw terminals