| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Forcibly guided output contacts max. | 2 NO contacts |
| Indicator contacts | 2 Semiconductor monitoring outputs |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 8 A |
| Width | 45 mm |
| Type | UH 6937 |
| Variant |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 NO contacts |
| Terminal type | pluggable terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
| Variant | Max. response value 600 Hz. With different frequency mode and analogue output |
The frequency monitor UH6937.02PS/001/61 DC24V from Dold is a safety-relevant monitoring switch for alternating voltages and rotation direction in industrial drive systems. It is used for safe frequency monitoring of single-phase or three-phase alternating voltages, as well as for monitoring phase sequence or rotation direction in three-phase systems. The device is specifically designed for use in drives, for example with frequency converters or slip ring rotor motors, as well as in crane systems. Parameterization is performed via a front-mounted display, enabling menu-guided adjustment of operating parameters. The display shows set and actual values for frequency and rotation direction. The maximum input frequency is 600 Hz, with variants /0_ _ supporting up to 700 Hz and /1_ _ up to 1200 Hz. The input voltage range is 8 to 280 V for single-phase and 16 to 690 V for single- and three-phase monitoring. The auxiliary voltage is DC 24 V.
Applications
The frequency monitor UH6937 is used in safety-critical applications, particularly for monitoring the output frequency of frequency converters and the rotor frequency of slip ring rotor motors. It is suitable for drives in crane systems, where reliable rotation direction and frequency monitoring is required. The functions include over-frequency, under-frequency, and window monitoring, as well as rotation direction monitoring. The devices are designed for use in safety applications up to PL e / Cat. 4 according to EN ISO 13849-1 and SIL 3 according to IEC/EN 62061. For rotation direction monitoring, the maximum safety category is PL d / Cat. 2 and SIL 2.
Functions and Equipment in Detail
The device features two forced-guided make contacts as output contacts, suitable for safe switching operations in safety systems. The contacts are galvanically isolated from the input and auxiliary voltage. Parameterization is performed via a front-mounted display, enabling comfortable, menu-guided adjustment. Adjustment options include variable hysteresis, a release delay of 0 to 100 seconds, a start-up bypass time of 0 to 100 seconds, and an alarm delay of 0 to 100 seconds. For rotation direction monitoring, a tolerance of 5 to 60000 cycles is adjustable. Alarm memory can be activated, as well as auto-reset. Indication is provided via LEDs and two semiconductor alarm outputs. An analog output (2 to 10 V) enables output of the current frequency value.
Technology Explained Simply
The frequency monitor operates using period duration measurement of the input frequency, ensuring a fast response time. The universal input terminals allow connection to various voltage ranges. Galvanic isolation between input, auxiliary voltage, and output contacts increases safety and prevents interference. Plug-in terminal blocks with screw terminals enable quick replacement of the device. The width is 45 mm, allowing compact mounting in standard control panels. The devices are designed for use in safety systems and comply with standards EN ISO 13849-1 and IEC/EN 62061.
Compatibility and Accessories
The frequency monitor is suitable for frequency converters up to 1200 Hz. The variant /_ _1 enables digital 4-bit selection of trigger values via a higher-level control system. The possibility of bypassing frequency and rotation direction monitoring (muting) and an adjustable switching bypass time of 0 to 100 seconds are integrated. The devices are equipped with various frequency modes and an analog output. Certifications include UL-listed C/US, TÜV, UKCA, and CCC.
Mounting and Installation
Mounting is performed in standard control panels with a width of 45 mm. The removable terminal blocks with screw terminals enable easy and secure wiring. Parameterization is performed directly on the device via the front-mounted display, allowing commissioning without a PC. The devices are designed for use in industrial environments and can be integrated into existing drive solutions.
Advantages in Operation
The comfortable parameterization via the front-mounted display reduces commissioning time. Extensive diagnostic functions enable quick fault detection and reduce plant downtime. Galvanic isolation and forced-guided contacts increase safety. Integrated alarm outputs and analog signal support monitoring and control in complex systems. The devices are designed for use in safety applications up to PL e / Cat. 4 and SIL 3, ensuring high reliability.