| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | For initiators |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Forcibly guided output contacts max. | 2 NO contacts |
| Indicator contacts | 2 Semiconductor monitoring outputs |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 8 A |
| Width | 45 mm |
| Type | UH 6932 |
| Variant |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 NO contacts |
| Terminal type | pluggable terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
| Variant | PNP-input |
The Dold speed monitor UH6932.02PS/010/61 DC24V is a safety-relevant monitoring switch for speed monitoring of drives in machines and plants. It serves to prevent hazards caused by moving machine parts and enables safe shutdown in case of critical speed deviations. The device is designed for use in industrial environments and features a front-mounted display that allows simple, menu-guided parameterization without additional control. The display enables setting and monitoring of setpoint and actual values in Hz, allowing precise adaptation to the specific application.
Applications
The speed monitor is designed for safety applications where speed monitoring of drives is required to prevent accidents or machine damage. It is used in the manufacturing industry, packaging industry, wood processing, and other areas where moving parts may pose a hazard. Functions such as overspeed, underspeed, or window monitoring make the device flexible for various drive systems.
Functions and Equipment in Detail
The device features a PNP input compatible with initiators such as inductive proximity switches from the NA 5001, NA 5002, NA 5005, or NA 5010 series. Input signals are evaluated via period duration measurement, resulting in a fast response time. Parameterization is done via the front-mounted display, where various response values can be set using a digital 4-bit selection. Additional functions include an adjustable hysteresis, a release delay of 0 to 100 seconds, a startup bypass time of 0 to 100 seconds, and an alarm delay in the same range. Alarm storage or auto-reset can also be configured.
Technology Explained Simply
The speed monitor operates with an auxiliary voltage of DC 24 V and is designed for use in safety circuits. The output contacts are forced-guided and consist of two normally open contacts (2 NO), supporting a maximum thermal current of 8 A. The outputs are suitable for use in safety-critical applications and comply with the requirements of standards EN ISO 13849-1 (PL e / Category 4) and IEC/EN 62061 (SIL 3). Diagnostic functions enable quick fault localization and reduce downtime. Two semiconductor alarm outputs serve for status indication and integration into higher-level control systems. The connection terminals are removable and designed as screw terminals, enabling quick replacement and easy installation.
Compatibility and Accessories
The speed monitor is compatible with initiators from the NA 5001, NA 5002, NA 5005, and NA 5010 series, which function as inductive proximity switches. Connection options are detailed in the manufacturer’s data sheets, with cable connections made via the device terminals. Initiators can be operated with either PNP or NPN outputs depending on type, while the UH6932.02PS/010/61 DC24V variant is specifically designed for PNP inputs. The connection terminals are suitable for various plug systems such as BA 9055, BH 5932, or IK/IL 9055, enabling flexible integration into existing installations.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The removable terminal blocks facilitate replacement and maintenance. The initiator cables are connected to the corresponding terminals, with color coding (brown, blue, black) and wiring assignments documented in the manufacturer’s connection tables. Parameterization is done via the display, with settings adjustable according to application. The devices are designed for industrial environments and comply with certifications UL-listed C/US, TÜV, UKCA, and CCC.
Operational Advantages
The speed monitor provides high safety by complying with standards PL e / Cat. 4 and SIL 3. Simple commissioning without a PC and menu-guided parameterization reduce installation time. Comprehensive diagnostic functions support maintenance and extend the operational life of the plant. Integration into existing drive solutions is straightforward, and multilingual support (German, English, French) simplifies operation. LED indicators and semiconductor alarm outputs ensure clear status indication and fast fault detection.
Certifications and Markings
The device is certified UL-listed C/US, TÜV, UKCA, and CCC. It meets safety requirements according to EN ISO 13849-1 (PL e / Cat. 4) and IEC/EN 62061 (SIL 3). These certifications guarantee suitability for safety-critical applications and compliance with international standards.
Contact Configuration and Output Capacity
The output contacts are forced-guided and consist of two normally open contacts (2 NO). The maximum thermal current is 8 A, sufficient for use in industrial circuits. The outputs are designed for use in safety systems and support requirements for safe shutdown.
Connection Technology and Width
The connection technology consists of removable screw terminals, ensuring secure and easy connections. The width is 45 mm, enabling integration into standard control panels. The removable terminal blocks facilitate replacement and maintenance of the device.
Adjustable Parameters
Parameters such as hysteresis, release delay, startup bypass time, and alarm delay are adjustable and can be adapted according to application. The startup bypass time can be set from 0 to 100 seconds to account for the plant’s startup process. The alarm delay allows a short tolerance period to avoid false alarms. Alarm storage or auto-reset can also be configured to adapt operation to specific requirements.
Initiator Compatibility
The speed monitor is compatible with initiators from the NA 5001, NA 5002, NA 5005, and NA 5010 series. Initiators can be operated with either PNP or NPN outputs depending on type, while the UH6932.02PS/010/61 DC24V variant is specifically designed for PNP inputs. Connection options are detailed in the manufacturer’s data sheets.
Diagnostic Functions
Comprehensive diagnostic functions enable quick fault localization and reduce downtime. LED indicators and semiconductor alarm outputs ensure clear status indication and fast fault detection. Diagnostic functions support maintenance and extend the operational life of the plant.
Safety Standards
The device complies with safety requirements according to EN ISO 13849-1 (PL e / Cat. 4) and IEC/EN 62061 (SIL 3). These certifications guarantee suitability for safety-critical applications and compliance with international standards.
Practical Application
The speed monitor is used in the manufacturing industry, packaging industry, wood processing, and other areas where moving parts may pose a hazard. Functions such as overspeed, underspeed, or window monitoring make the device flexible for various drive systems. Simple commissioning without a PC and menu-guided parameterization reduce installation time. Integration into existing drive solutions is straightforward, and multilingual support (German, English, French) simplifies operation.
Certifications and Markings
The device is certified UL-listed C/US, TÜV, UKCA, and CCC. It meets safety requirements according to EN ISO 13849-1 (PL e / Cat. 4) and IEC/EN 62061 (SIL 3). These certifications guarantee suitability for safety-critical applications and compliance with international standards.
Contact Configuration and Output Capacity
The output contacts are forced-guided and consist of two normally open contacts (2 NO). The maximum thermal current is 8 A, sufficient for use in industrial circuits. The outputs are designed for use in safety systems and support requirements for safe shutdown.
Connection Technology and Width
The connection technology consists of removable screw terminals, ensuring secure and easy connections. The width is 45 mm, enabling integration into standard control panels. The removable terminal blocks facilitate replacement and maintenance of the device.
Adjustable Parameters
Parameters such as hysteresis, release delay, startup bypass time, and alarm delay are adjustable and can be adapted according to application. The startup bypass time can be set from 0 to 100 seconds to account for the plant’s startup process. The alarm delay allows a short tolerance period to avoid false alarms. Alarm storage or auto-reset can also be configured to adapt operation to specific requirements.
Initiator Compatibility
The speed monitor is compatible with initiators from the NA 5001, NA 5002, NA 5005, and NA 5010 series. Initiators can be operated with either PNP or NPN outputs depending on type, while the UH6932.02PS/010/61 DC24V variant is specifically designed for PNP inputs. Connection options are detailed in the manufacturer’s data sheets.
Diagnostic Functions
Comprehensive diagnostic functions enable quick fault localization and reduce downtime. LED indicators and semiconductor alarm outputs ensure clear status indication and fast fault detection. Diagnostic functions support maintenance and extend the operational life of the plant.
Safety Standards
The device complies with safety requirements according to EN ISO 13849-1 (PL e / Cat. 4) and IEC/EN 62061 (SIL 3). These certifications guarantee suitability for safety-critical applications and compliance with international standards.
Practical Application
The speed monitor is used in the manufacturing industry, packaging industry, wood processing, and other areas where moving parts may pose a hazard. Functions such as overspeed, underspeed, or window monitoring make the device flexible for various drive systems. Simple commissioning without a PC and menu-guided parameterization reduce installation time. Integration into existing drive solutions is straightforward, and multilingual support (German, English, French) simplifies operation.