| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | For initiators |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Forcibly guided output contacts max. | 2 NO contacts |
| Indicator contacts | 2 Semiconductor monitoring outputs |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 8 A |
| Width | 45 mm |
| Type | UH 6932 |
| Variant |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 NO contacts |
| Terminal type | pluggable terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
| Variant | NPN-Input |
The Dold speed monitor UH6932.02PS/61 DC24V is a safety-relevant monitoring switch for speed control in industrial drive systems. It is designed for the safe detection of overspeed, underspeed, or window speed conditions, preventing hazards caused by moving machine parts. The device is intended for use in machines and plants where precise and reliable speed monitoring is required. Parameterization is performed via a front-mounted display, enabling menu-guided setting of values, which allows for quick and easy commissioning without external control or PC.
Applications
The speed monitor is designed for safety applications requiring high reliability. It is used in drive systems where speed deviations can cause damage or hazards. Application areas include, for example, monitoring of motors, gearboxes, conveyor systems, or machine tools. Integrated diagnostic functions enable rapid fault detection, thereby reducing plant downtime. The device class is designed for initiators, meaning it can be directly connected to inductive proximity switches such as Dold models NA 5001, NA 5002, NA 5005, or NA 5010.
Functions and Equipment in Detail
The device features an NPN input, compatible with corresponding initiators. Setting of trigger values is done digitally via a 4-bit selection, allowing various speed ranges to be configured. Display of setpoint and actual values is in Hz, enabling precise monitoring. Response time is short, as the input frequency is measured via period duration measurement. Additional functions include an adjustable hysteresis, a release delay of 0 to 100 seconds, a start-up bypass time of 0 to 100 seconds, and an alarm delay in the same range. Alarm storage or auto-reset can be configured to adapt operation to the requirements of the plant.
Technology Explained Simply
The speed monitor operates with an auxiliary voltage of DC 24 V and is designed for use in 2-channel systems. The output contacts are forced-guided, meaning they are mechanically linked, ensuring a secure switching function. The maximum thermal current load is 8 A, defining the contact load capacity. The output contacts consist of two closers, suitable for controlling safety functions. Two semiconductor alarm outputs serve for status indication and can be integrated into monitoring systems. Connection is made via removable terminal blocks with screw terminals, enabling quick replacement of the device. The width is 45 mm, allowing compact mounting in standard control panels.
Compatibility and Accessories
The speed monitor is compatible with inductive proximity switches of types NA 5001, NA 5002, NA 5005, and NA 5010. Connection options are detailed in the manufacturer’s data sheets, with connections made via device terminals. Initiators can be used in various variants (PNP, NPN, PNP/NPN), with variants NA 5002.01.34 and NA 5005.01.34 only suitable for devices without initiator connection detection. The initiator connection cables have a length of 2 m and are designed for secure connections. The IP 67 protection rating of the initiators ensures dust- and water-tight enclosure, enabling use in outdoor or damp environments.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. Removable terminal blocks facilitate replacement and maintenance of the device. Initiator connection cables are connected to the corresponding terminals, with color coding (brown, blue, black) aiding identification. Parameterization is done via the front-mounted display, requiring no additional tools or software. Settings can be adjusted at any time to meet the requirements of the respective plant.
Operational Advantages
Operation of the speed monitor is particularly user-friendly due to integrated diagnostic functions and simple parameterization via the display. The fast response time and precise speed measurement via period duration measurement ensure reliable monitoring. The ability to bypass speed monitoring (muting) allows flexible use, for example during start-up. Certifications UL-listed C/US, TÜV, UKCA, and CCC, along with safety classes PL e / Cat. 4 according to EN ISO 13849-1 and SIL 3 according to IEC/EN 62061, confirm suitability for safety-critical applications. Multilingual operation (German, English, French) facilitates use in international environments.