| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 5 - 10500 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | Without sensor detection. PNP-input. Adjustable setting value channel 1 and 2 together adjustable with fine tuning to synchronise both channels |
The Dold speed monitor BH5932.22/013/61 ACDC24V 5-10500IPM is a safety-relevant monitoring switch for continuous monitoring of rotational and linear movements in machines and plants. It is used to prevent hazards caused by moving machine parts and is typically employed in industrial applications where safe shutdown is required in case of standstill or unauthorized movement. The device is designed for use with initiators, particularly inductive proximity switches, and features a 2-channel design enabling redundant monitoring.
Applications
This speed monitor is suitable for use in machine building, packaging technology, material handling, and other industries involving moving parts, where safe motion monitoring is required. It monitors the speed of drives and safely shuts off when a predefined trigger value is reached or when standstill occurs. Applications are particularly common in systems that must be certified according to safety standards such as EN ISO 13849-1 or IEC/EN 62061.
Functions and Features in Detail
The device features an adjustable trigger value ranging from 5 to 10500 IPM (impulses per minute), set simultaneously for both channels. The switching simultaneity of the channels can be optimized via fine adjustment to ensure synchronized response. The inputs are designed for pnp proximity switches, with the variant without initiator connection detection. A feedback circuit X1–X2 enables monitoring of external contacts, facilitating integration into existing safety circuits.
Technology Explained Simply
The speed monitor operates at a nominal voltage of AC/DC 24 V and is rated for a thermal load of up to 4 A. The output contacts are forced-guided, consisting of 2 normally closed contacts and 1 normally open contact, ensuring safe and redundant signal transmission. The width is 45 mm, allowing compact mounting in standard control panels. The contacts are designed for wire connections of 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with sleeve DIN 46 228-1/-2/-3.
Compatibility and Accessories
The device is compatible with inductive proximity switches from the NA 5001, NA 5002, NA 5005, and NA 5010 series. In particular, types NA 5002.01.34 and NA 5005.01.34 are intended for devices without initiator connection detection. The terminal assignment is detailed in the datasheet for device class BH 5932, including the colour coding of wires (brown, blue, black, white) and their assignment to inputs In A / In B and outputs NO and NC.
Mounting and Installation
Mounting is carried out in standard control panels with a width of 45 mm. The terminal clamps are designed for the specified wire cross-sections, and the use of sleeves and plastic collars is recommended. Electrical connections are made via designated terminals, ensuring correct wire assignment according to the terminal table. The devices are designed for industrial environments, with ambient temperatures ranging from -25 °C to +70 °C.
Operational Advantages
The speed monitor provides high safety performance with Category 3 and Performance Level e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061. The forced-guided contacts ensure safe signal transmission, and the redundant 2-channel design increases reliability. The adjustable speed monitoring allows flexible adaptation to different drive conditions. Certifications including UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards.