Dold 0066427, EAN: 4030641664275

Dold 0066427 RN9877.11/010/61 3AC175-525V 4-20% phase monitor 0-30 s

Dold 0066427 RN9877.11/010/61 3AC175-525V 4-20% phase monitor 0-30 s

Lieske Part No. 1002080
Mfg Part No 0066427
EAN-Code 4030641664275
Manufacturer Dold
Here only 174,16 EUR
207,25 EUR incl. VAT

Further information for Dold 0066427 RN9877.11/010/61 3AC175-525V 4-20% phase monitor 0-30 s

Technical data
1- / 3-phase1, 3
ApprovalsUL
Auxiliary voltageWithout
Enclosure designDistribution board
Measuring range max.525 V
Output contacts1 C/O contact
Standard measuring range3/N AC 175 - 525 V / 100 - 300 V
Width52,5 mm
TypeRN 9877
Variant
Contact equipping1 changeover contact
Hysteresis4 - 20 %
Measuring voltage3AC 175 - 525 V
Switching delay0 - 30 s
Approvals and MarkingsUL-listed C/US
VariantDe-energized on trip. Without neutral. Voltage monitoring
The phase monitor RN9877.11/010/61 from Dold is an industrial measuring relay type from the VARIMETER series, designed for monitoring AC and three-phase power networks. The width is 52.5 mm, making it suitable for installation in installation distributors.

Applications
The phase monitor is used in industrial plants where the reliability of power supply is critical for the operation of motors, pumps, and other electrical consumers. It is particularly suitable for installations where incorrect phase sequence or phase failure can cause damage, for example in production plants, pump stations, or drives with three-phase motors. Early detection of voltage failures, overvoltage, or asymmetries enables preventive maintenance and prevents costly downtime.

Functions and equipment in detail
The device monitors multiple parameters: overvoltage, undervoltage, voltage range exceedance, phase asymmetry, phase failure, and incorrect phase sequence. The monitoring functions can be easily selected via a function selector switch, without complex menu structures. Measurement is performed in the range of 3AC 175 to 525 V, and single-phase systems from 100 to 300 V can also be monitored. The hysteresis is adjustable and ranges from 4 to 20 %, enabling stable return to normal state. The switching delay is also adjustable and ranges from 0 to 30 seconds, filtering out short-term voltage fluctuations.

Technology explained simply
The phase monitor uses the voltage from the three phases for internal power supply, eliminating the need for additional auxiliary voltage. This reduces wiring effort and increases installation flexibility. The output contact configuration includes a changeover contact, which interrupts the circuit in case of fault. LED indicators signal the respective fault condition, for example overvoltage, undervoltage, or asymmetry. The functions are designed to react quickly and reliably to deviations, thereby increasing the operational safety of the installation.

Compatibility and accessories
The device is designed for use in 3-phase and 1-phase networks and can be operated with or without neutral conductor connection. The monitoring functions are universally applicable and can be selected according to the application. No special accessories are required, as all necessary functions are integrated into the device. The UL-listed C/US certification confirms suitability for use in North America.

Mounting and installation
The phase monitor is installed in installation distributors and features connection terminals for phases L1, L2, L3, and optionally for neutral conductor N. The output contacts (11, 12, 14) are intended for connection to external switching devices or controls. Mounting is done in standard distributor enclosures with a width of 52.5 mm. Adjustments for hysteresis and switching delay are made via mechanical settings on the device.

Operational advantages
By detecting voltage anomalies and phase faults early, the phase monitor enables preventive maintenance, increasing productivity and preventing damage to installations. High repeatability and a wide measurement voltage range ensure reliable monitoring under various operating conditions. Simple operation via a function selector switch reduces error susceptibility during commissioning and maintenance. Operational safety is ensured by continuous monitoring and rapid response to fault conditions.

Approvals and standards
The device complies with IEC/EN 60255-1 and is UL-listed C/US, confirming compliance with international safety and quality standards. These approvals guarantee suitability for use in industrial installations and regions with specific requirements for electrical measuring instruments.

Enclosure design
The device is designed as an installation distributor, enabling easy mounting in standard distributor enclosures. The width of 52.5 mm corresponds to the standard for modular components in distributors.

Adjustable parameters
The hysteresis is adjustable in the range of 4 to 20 %, allowing flexible adaptation to specific requirements. The switching delay can be set from 0 to 30 seconds to ignore short-term voltage fluctuations and detect only relevant fault conditions. These settings are adjusted via mechanical controls on the device.

Connection terminals
The connection terminals are provided for phases L1, L2, L3, and optionally for neutral conductor N. The output contacts 11, 12, 14 are for connecting to external switching devices.

Function selector switch
Via a function selector switch, the monitoring functions can be selected: overvoltage (U>), undervoltage (U<), voltage range (U<>), phase asymmetry (Asym.), and phase sequence. Selection is done without menu structure, simplifying operation and reducing the risk of incorrect operation.

LED indicators
The LED indicators signal the respective fault condition: overvoltage, undervoltage, asymmetry, phase failure, or incorrect phase sequence. The LEDs light up in case of fault, enabling quick visual diagnosis of the problem.

Operational safety
Operational safety is ensured by continuous monitoring and rapid response to fault conditions. Preventive maintenance, enabled by early detection of impending failures, increases plant availability and reduces maintenance costs.

Application areas
The phase monitor is suitable for use in installations with motor loads, pump stations, production plants, and other industrial systems where power supply reliability is critical. It can also be used to switch to a safety power supply after detecting a fault condition.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1002080
qrcode für Dold 0066427 RN9877.11/010/61 3AC175-525V 4-20% phase monitor 0-30 s