Further information for Dold 0066274 UG9256.11/011/61 3AC200-480V 1-10S motor starter soft start 9A
Technical data
1- / 3-phase
3
Approvals
UL
Auxiliary voltage
DC 24 V
Load current up to
9 A
Load voltage up to
3AC 200 - 480 V
On/Off Input Control
DC
Width
22,5 mm
Type
UG 9256
Signalling output
Temperature monitoring
Variant
Contact equipping
1 changeover contact
Nominal current
9 A
Nominal voltage
3AC 200 - 480 V
Ramp time
1 - 10 s
Approvals and Markings
UL-listed C/US, UKCA
Variant
With softstart. Without mains isolating relay, on when no failure. Motor protection
The Dold UG9256.11/011/61 is an intelligent motor starter of the MINISTART series, specifically designed for industrial applications with 3-phase asynchronous motors. The device combines soft start, direction reversal, and motor protection functions in a compact module. It is rated for nominal voltages of 3AC 200 to 480 V and features a nominal current of 9 A. The width is 22.5 mm, enabling up to 80 % space saving compared to conventional solutions. Control is achieved via digital inputs with a 24 V DC auxiliary voltage. The device includes semiconductor temperature monitoring to ensure high device availability and provides galvanic isolation between control and main current circuits.
Applications
The motor starter is intended for applications requiring soft start and controlled direction change, such as door and gate drives, bridge drives, lifting systems, and conveyor systems with blocking protection. The integrated current monitoring detects overloads when the set current value is exceeded for more than 2 seconds, and shuts off the motor. Direction reversal is achieved via relays that switch without current, extending contact life. Application areas include motors with power ratings of 30 W to 150 W, 90 W to 750 W, or 550 W to 4 kW at an operating voltage of AC 400 V.
Functions and Equipment in Detail
The device offers up to six functions in one module: soft start, soft stop, direction reversal (left and right rotation), current monitoring, and motor protection. The soft start and soft stop functions are implemented using thyristors, where two motor phases are driven via phase control to ensure a smooth increase in current and torque. The ramp time is adjustable between 1 and 10 seconds. Direction reversal is achieved via relays that switch without current to minimize wear. A signal relay indicates operational readiness when no fault is present. Settings are adjusted via potentiometers on absolute scales, enabling simple and time-saving commissioning.
Technology Explained Simply
The UG9256.11/011/61 combines the advantages of robust relay technology with wear-free semiconductor technology. Main functions such as soft start and soft stop are implemented using thyristors, enabling phase-controlled current supply. Direction change is achieved via mechanical relays that switch without current to increase lifespan. Semiconductor temperature monitoring ensures high availability, as the device shuts off in case of overheating. Galvanic isolation between control and main current circuits is achieved via forced-contact contacts with a minimum contact gap of 0.5 mm, ensuring safe insulation. The voltage withstand of the semiconductors is up to 1500 V.
Compatibility and Accessories
The device is compliant with IEC/EN 60947-4-2 and carries the certifications UL-listed C/US and UKCA. Control is via galvanically isolated 24 V inputs for right and left rotation. A reset button is integrated on the device front, and an external reset button can be connected. A signal output is available to indicate operational readiness. The current monitoring can optionally be switched off. The connection terminals are designed for connection to the respective cables.
Mounting and Installation
Mounting is in standard control panels with a width of 22.5 mm. The device connection terminals are designed for connection to main and control cables. Commissioning is performed via adjustment controls (potentiometers) on the front, calibrated on absolute scales. Status indication is provided via four LEDs that visually signal the operating state. Installation requires no special tools, as settings can be adjusted directly on the device.
Operational Advantages
The motor starter reduces mechanical stress during start-up and shutdown, as the soft start and soft stop control torque development. The integrated motor protection function protects the motor from overloads and blockages. Galvanic isolation increases operational safety. The compact design and simple operation via potentiometers with absolute scales enable quick commissioning. Semiconductor temperature monitoring ensures high operational reliability and extends the device's lifespan. The current-free relay switching minimizes wear and increases reliability.