Dold 0066140, EAN: 4030641661403

Dold 0066140 MH9398.11 AC12-230V UHAC230V AC10A active power transducer

Dold 0066140 MH9398.11 AC12-230V UHAC230V AC10A active power transducer

Lieske Part No. 1002393
Mfg Part No 0066140
EAN-Code 4030641661403
Manufacturer Dold
Here only 425,18 EUR
505,96 EUR incl. VAT

Further information for Dold 0066140 MH9398.11 AC12-230V UHAC230V AC10A active power transducer

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Measuring range max.10 A
Output contacts1 C/O contact
Width45 mm
TypeMH 9398
Variant
Auxiliary voltageAC 230 V
Contact equipping1 changeover contact
Measuring currentAC 10 A
Measuring voltageAC 12 - 230 V
VariantAnalogue output and C/O contact
The active power transducer MH9398.11 from Dold is a single-phase monitoring device for measuring and controlling the active power of electrical consumers, particularly in industrial applications with variable motor loads. The device is part of the VARIMETER family and is designed for reliable detection of overload conditions by measuring the actual active power in watts. It features an adjustable threshold value, which can be easily and precisely set using two rotary switches. When the set limit is exceeded, the integrated output relay activates, enabling a response to overload or reverse power conditions. Additionally, the device offers two galvanically isolated analog outputs, allowing real-time querying of the current active power value. The status is indicated via LEDs, which signal the applied auxiliary voltage and the relay switching state. In case of overload in the current range, the LEDs flash rapidly to alert the operator of a fault.

Applications
This transducer is specifically designed for monitoring single-phase electrical drives and consumers operated under variable load conditions. It is suitable, for example, for monitoring pumps, fans, heaters, or other single-phase motors in industrial and commercial installations. Its ability to detect reverse power makes it particularly suitable for applications where the motor may switch to generator mode under load, such as during downward motion or mechanical braking operations.

Functions and Equipment in Detail
The device operates on the zero-current principle, consuming only a small amount of power during normal operation. The auxiliary voltage is AC 230 V, which may vary between 0.8 and 1.1 times the nominal voltage. The measurement voltage range is AC 12 to 230 V, while the measurement current can reach up to AC 10 A. The maximum current measurement range is 10 A, with continuous overload up to 16 A and short-term overload (under 10 seconds) up to 25 A. The threshold value is adjusted using two rotary switches: an upper switch for fine adjustment (0 to 0.3 kW) and a lower switch for range selection (8 ranges from 0 to 2.4 kW). The hysteresis is fixed to prevent false alarms due to minor fluctuations.

Technology Explained Simply
The transducer measures active power, i.e., the actual electrical power in watts consumed by a load. This is achieved by simultaneously measuring voltage and current, taking phase shift into account. The measurement is performed in the frequency range of 45 to 400 Hz, enabling use in various power networks. The galvanic isolation of the analog outputs (optionally 0…20 mA and 0…10 V or 4…20 mA and 2…10 V) ensures safe and interference-free transmission of measurement values to external systems. The LED indicators provide visual feedback on the operating status, with the green LED indicating auxiliary voltage and the other LED indicating the relay status.

Compatibility and Accessories
The device is designed for installation in enclosures and has a width of 45 mm. The connection terminals are standardly equipped with screw or spring-cage terminals, with optional plug-in terminal blocks available to speed up device replacement. The terminal markings are clearly defined: A1/A2 for auxiliary voltage, N/i and L for voltage input, i/k for current measurement path, 11/12/14 for the changeover contact, and U/I/G/X1 for the analog outputs.

Mounting and Installation
Mounting is carried out in an enclosure, with wiring of the terminals according to the connection diagrams. The phase current L1 is connected via terminals i and k. For currents exceeding 10 A, an external current transformer must be installed. The auxiliary voltage is supplied via A1/A2. The threshold value is set before commissioning, selecting the desired power level using the two rotary switches.

Operational Advantages
Active power measurement enables precise overload detection, independent of voltage or current waveform. This leads to extended service life of electrical drives, as overloads are detected and switched off early. The analog outputs allow integration into higher-level control and monitoring systems, enabling preventive maintenance and faster fault localization. The clear LED display supports the operator in quickly diagnosing operating conditions.

Standards and Approvals
The device complies with IEC/EN 60255-1, the standard for electrical measuring instruments in industrial applications. The nominal frequency is 50/60 Hz, and the device is designed for operation in the frequency range of 45 to 400 Hz. The current consumption at AC 230 V is 15 mA, and the nominal power consumption is 2.5 W. The measurement ranges for voltage and current are clearly defined, with voltage measurement in the range AC 12 to 230 V and current measurement in the range AC 100 mA to 10 A.

Enclosure Design and Mounting
The device is designed for enclosure mounting and has a width of 45 mm. The terminals are designed for secure connections, with the option of plug-in terminal blocks simplifying maintenance and replacement. Terminal markings are clearly labeled to prevent incorrect wiring.