Technical data
1- / 2-channel2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ClassificationFor initiators and encoders
ConnectionPluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals
Forcibly guided output contacts max.2 x 2 NO contacts
Indicator contacts2 Semiconductor monitoring outputs
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width45 mm
TypeUH 5947
Variant
Contact equipping4 NO contacts
Nominal voltageDC 24 V
Terminal typepluggable terminal blocks with screw terminals
Approvals and MarkingsUL-listed C/US, TÜV, UKCA, CCC
VariantFor PNP- NPN sensors. At sensor selection E1+E2: The semiconductor outputs give out the incoming signal of E1 with a ratio 1:2. Other sensor selection: The emiconductor outputs have no function
The Dold speed monitor UH5947.04PS/100/61 DC24V is a safety-relevant monitoring switch for speed monitoring of drives in machines and plants. It serves to prevent hazards caused by moving machine parts and enables safe monitoring of speeds in automatic and setup operation, as well as safe standstill monitoring. The device is designed for use in safety applications up to safety performance level PL e / Category 4 according to EN ISO 13849-1 and SIL 3 according to IEC/EN 62061. The integrated safety door monitoring reduces space and cost requirements, as external safety door monitoring devices can be omitted. Parameterization is performed via a front-mounted, menu-guided display, enabling commissioning without a PC. Settings can also be transferred via an RJ45 connection (FCC Western-Modular 8P8C) with a connecting cable, enabling a copy function between devices.

Applications

The speed monitor is intended for use in industrial machines and plants where safe speed and standstill monitoring is required. It is suitable for drives operated with various motor feedback systems and proximity switches. The application includes monitoring of speeds in automatic and setup operation, with the standstill path permanently enabled during setup operation. The integrated safety door monitoring can be configured in single- or dual-channel versions. The device is designed for monitoring release magnets and feedback circuits and supports activation of output paths via a single-button with short-circuit detection or automatic single-function.

Functions and Equipment in Detail

The device features a dual-channel circuit with forced-guided output contacts. The contact configuration includes 4 normally open contacts arranged in two separate output paths (e.g. 43/44, 53/54). Connection technology uses removable terminal blocks with screw terminals, with variants featuring spring-loaded terminals also available. The rated voltage is DC 24 V, and the maximum thermal current Ith is 5 A. Device indicators include LED indicators and 2 semiconductor alarm outputs, which, when sensor selection E1 + E2 is chosen, output the signal from E1 in a 1:2 ratio. For other sensor selections, the semiconductor outputs are non-functional. Parameterization is performed via a front-mounted display, enabling display of setpoint and actual values in rpm or m/min, as well as setpoint display as a frequency value. Adjustable functions include start-up bypass (0 ... 999 s), release delay time (0 ... 999 s), and shutdown monitoring for external contactors at RF1 (0.5 ... 999 s). The device supports configuration of PNP or NPN initiators and can operate with various encoders (sin/cos, TTL, HTL).

Technology Explained Simply

The speed monitor UH5947 operates with a dual-channel design, enabling redundant monitoring. The forced-guided output contacts ensure that contacts are only opened or closed in defined, safe states, which is crucial for safety functions. The integrated safety door monitoring allows safety functions to be combined directly within the device, eliminating the need for external circuits. The display on the front-mounted screen enables intuitive operation and parameterization. Diagnostic functions support fault detection and reduce downtime. Transferring device parameters via a button press to other devices simplifies commissioning and maintenance. The device width is 45 mm, enabling compact mounting in standard control panels.

Compatibility and Accessories

The device is designed for use with various initiators and encoders, including sin/cos, TTL, and HTL signals. It is suitable for safety functions such as STO, SOS, SLS, SSM, SSR, and SDL according to EN 61800-5-2. The connection terminals are removable and can be equipped with screw or spring-loaded terminals depending on the variant. Device parameters can be transferred via RJ45 connection, requiring a connecting cable. The devices are designed for use in safety applications up to PL e / Cat 4 and SIL 3.

Mounting and Installation

Mounting is performed in standard control panels with a width of 45 mm. The connection terminals are removable, facilitating replacement and maintenance. Parameterization is performed via the front-mounted display, eliminating the need for additional software or PC connection. Settings can be made via the display or via the RJ45 connection. The devices are designed for use in industrial environments and comply with certifications UL-listed C/US, TÜV, UKCA, and CCC.

Operational Advantages

The speed monitor UH5947 offers a compact, integrated solution for safe speed and safety door monitoring. The integrated safety door monitoring reduces space and cost requirements. The menu-guided parameterization via the front-mounted display enables quick and easy commissioning. Diagnostic functions support fault detection and reduce downtime. The copy function via RJ45 connection simplifies parameterization of multiple devices. Support for various encoder and initiator types increases flexibility when integrating into existing drive solutions. The devices are designed for use in safety applications up to PL e / Cat 4 and SIL 3, ensuring high safety performance. Display of setpoint and actual values in various units (rpm, m/min, frequency) supports monitoring and diagnostics. Adjustable start-up bypass, release delay, and shutdown monitoring enable application-specific configuration. Multilingual support (German, English, French, Italian, Spanish) facilitates operation in international environments.