| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 20 - 2600 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | With sensor detection. NPN-input. Adjustable setting value channel 1 and 2 separated adjustable |
The Dold speed monitor BH5932.22/102/61 AC/DC24V is a safety-relevant monitoring switch for industrial applications. It is designed for continuous monitoring of rotational and linear movements in machines and plants, to prevent hazards caused by moving parts for both personnel and machinery. The device is designed for use in safety-critical applications and meets the requirements for high functional safety.
Applications
The BH5932 is used in industrial automation, particularly in machines containing moving parts such as drives, shafts, or conveyor belts. It monitors the speed or standstill of motors and drive units, initiating a safe shutdown in case of deviations from predefined values. The application is in environments where high availability and reliability of safety functions are required, for example in packaging, conveying technology, or machine tool industries.
Functions and Equipment in Detail
The device features a 2-channel design, enabling two independent monitoring channels. The response values range from 20 to 2600 impulses per minute (IPM), covering a wide range of applications. The contact configuration includes 2 normally open contacts and 1 normally closed contact, implemented as forced-guided contacts to ensure secure signal transmission even in the event of mechanical interference. The initiator connection detection ensures that the connection to proximity switches is monitored, preventing false alarms caused by interrupted or defective sensors.
Technology Explained Simply
The BH5932 operates with an NPN input, designed for connection to inductive proximity switches. The inputs are designed to be compatible with sensors such as Dold Minitiator types NA 5001, NA 5002, NA 5005, or NA 5010. The terminal clamps allow connection of wires with a cross-section of up to 2.5 mm², including cables with ferrules and plastic collars according to DIN 46 228-1/-2/-3/-4. The rated voltage is AC/DC 24 V, enabling universal use in industrial control systems. The maximum thermal current is 4 A, defining the contact load capacity.
Compatibility and Accessories
The device is compatible with Dold Minitiator proximity switches NA 5001, NA 5002, NA 5005, and NA 5010. The connection combinations are detailed in the data sheet, with devices featuring initiator connection detection specifically designed for use with types NA 5001.01.20, NA 5002.01.34, NA 5005.01.34, and NA 5010.01.20. The terminal clamps are designed to ensure secure and reliable connection to the sensors. The use of sensors with IP67 protection rating is recommended, as they are suitable for outdoor or humid environments.
Mounting and Installation
The BH5932 has a width of 45 mm, making it suitable for standard control panels according to DIN EN 60715. Mounting is done in an enclosure or control console, ensuring the terminals for sensor and load connections are accessible. The connection cables should be routed according to the specifications in the data sheet to ensure secure and interference-free signal transmission. The devices are designed for industrial environments and require no special mounting tools.
Advantages in Operation
The BH5932 offers high safety performance with Category 3 and Performance Level e according to EN ISO 13849-1, as well as SIL 3 classification according to IEC/EN 62061. These certifications guarantee high reliability and are required for safety-critical applications. The forced-guided contacts prevent unintended signal transmission, and the initiator connection detection ensures continuous monitoring of sensors. The adjustable response values allow precise adaptation to specific applications, achieving optimal operational safety. The certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards.
Approvals and Safety Standards
The device complies with the requirements of standards EN ISO 13849-1 (Category 3, PL e) and IEC/EN 62061 (SIL 3). These standards define requirements for safety-related controls and guarantee high functional reliability. The approvals UL-listed C/US, TÜV, and CCC confirm compliance with respective safety and quality requirements in the USA, Germany, and China. The devices are suitable for use in safety-critical applications and can be employed in systems with increased requirements for operational safety.