| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | For initiators and encoders |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Forcibly guided output contacts max. | 2 x 2 NO contacts |
| Indicator contacts | 2 Semiconductor monitoring outputs |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | UH 5947 |
| Variant |
| Contact equipping | 4 NO contacts |
| Nominal voltage | DC 24 V |
| Terminal type | pluggable terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
| Variant | For PNP- NPN sensors. The transistor outputs 38 and 68 are continuously on when the unit is on operation and are switched off as soon as failure is detected |
The Dold speed monitor UH5947.04PS/200/61 DC24V is a safety-relevant monitoring switch for speed and standstill monitoring in industrial drive systems. It is designed for the safe monitoring of machine movements to prevent hazards to personnel and machinery. The device is designed for use in safety applications up to Category 4 and PL e according to EN ISO 13849-1 as well as SIL 3 according to IEC/EN 62061. It features a 2-channel design and integrated safety door monitoring, which eliminates the need for external safety components. Parameterization is performed via a front-mounted, menu-guided display, enabling the setting of speed ranges, operating modes, and diagnostic functions. The display shows values in rpm or m/min, with the setpoint additionally displayed as a frequency value.
Applications
The speed monitor is intended for use in machines and plants where moving parts or drives may pose a hazard. It is suitable for drives with various motor feedback systems and proximity switches. The integrated safety door monitoring enables monitoring of safety doors in single- or dual-channel technology, reducing the number of required safety components. The device can be used in automatic and setup operation, with the standstill path permanently enabled in setup mode. Applications also include monitoring of release magnets and feedback circuits, as well as detection of shaft breaks via an adjustable gear ratio between two sensors.
Functions and Equipment in Detail
The device features forced-guided output contacts with a maximum configuration of 2 x 2 normally closed contacts. The contact configuration includes 4 normally closed contacts, suitable for safe load control. Connection is made via removable terminal blocks with screw terminals, enabling quick replacement and flexible installation. Alternatively, removable spring-cage terminals are also available. The nominal voltage is DC 24 V, and the maximum thermal current (Ith max.) is 5 A. Device parameters can be transferred via the display or an RJ45 connection (FCC Western-Modular 8P8C) using a connecting cable, enabling a copy function. Settings are change-tracked to ensure traceability.
Technology Explained Simply
The speed monitor monitors the rotational speed of a drive and responds to deviations from predefined speed ranges. It detects system faults, such as interruption of feedback circuits or failure of the release magnet, and de-energizes the outputs. The semiconductor alarm outputs (38 and 68) are continuously energized in fault-free operation and de-energized when a fault is detected. Operating modes are adjustable, with automatic mode covering monitoring of a speed window and standstill. In setup mode, only the setup speed window is monitored, while the standstill path remains enabled. Start-up bridging and release delay time are adjustable (0 to 999 seconds), as is the shutdown monitoring for external contactors at RF1 (0.5 to 999 seconds).
Compatibility and Accessories
The device is configurable for PNP and NPN initiators and can be connected to various encoders (sin/cos, TTL, HTL). It is suitable for use with STO, SOS, SLS, SSM, SSR, and SDL in accordance with EN 61800-5-2. The terminal connectors are removable, allowing for quick replacement. The devices are designed for integration into existing drive solutions and support parameter transfer via button press to other devices. The user interface is multilingual (German, English, French, Italian, Spanish) and enables comfortable parameterization.
Mounting and Installation
Mounting is performed in standard control panels with a width of 45 mm. The terminal connectors are removable, enabling flexible and quick installation. The devices are designed for use in industrial environments and comply with certifications UL-listed C/US, TÜV, UKCA, and CCC. Installation requires no special tools, as the terminals are equipped with screw or spring-cage technology.
Advantages in Operation
The speed monitor reduces downtime through comprehensive diagnostic functions and enables easy commissioning without a PC. The integrated safety door monitoring saves space and costs by eliminating external components. Parameter transfer via button press simplifies maintenance and configuration. The devices are designed for high safety and comply with safety function standards up to PL e / Cat 4 and SIL 3. LED indicators and semiconductor alarm outputs support fault detection and diagnostics during operation.